At Vito Services in Chevy ChaseMD, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Chevy Chase’s most capable hands, and let us improve your living standards because you’re entitled to the best.

We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the Chevy ChaseMD community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!

Recent Jobs and Reviews in Chevy Chase, MD

Job Locations and Reviews

Bobby I.
Bobby I. Checked in
Plumbing Call for Leaking Pipe Off Water Heater 06/12/2024 Examined area of concern by customer. Customer concerned about scaling around nipple. Appears there was a leak in area in past. All is dry and secured with no leaks visible. Inspection of area produced Ball valve above has leaked at some point. Also, water heater was installed in 2020 and never inspected and not installed within local plumbing codes. Formulated options to properly pipe in cold side per local plumbing codes. Customer would like opportunity to contact installation technician and have him rectify and will contact us for assistance if required at proposed investment option. Thank you for choosing Vito!
Chevy Chase, MD 20815
Anthony V.
Anthony V. Checked in
Emergency Plumbing Call Sunday 06/09/2024 I arrived onsite, basement laundry sink backing up individually and also when running 1st floor kitchen faucet above. basement kitchen sink drain affected as well. located cleanout approximately 5 feet downstream from laundry sink. removed PVC cap from wye fitting and set up drop cloth and K-50. snaked approximately 45 feet with K-50 based on previous job site history. pulled back cables and found roots on cable head. ran laundry faucet, upstairs kitchen faucet and basement kitchen faucet simultaneously. drain line started to back up within 10 minutes of running all 3 faucets. snaked line again with K-50, this time putting in approximately 60 feet of cables. pulled back snaking cables and ran all 3 faucets simultaneously for 20 minutes. stopped up basement k/s and released stopper a few times. basement k/s draining well. checked all sinks for proper drainage. re connected PVC cap on cleanout. recommended customer have drain line scoped with cam
Chevy Chase, MD 20815
Leon T.
Leon T. Checked in
AC Maintenance 06/10/2024 Lennox I checked the filter was dirty then I replaced .I check indoor blower I check the indoor wheel compartment for any construction found none. I checked the blower capacitor it doesn't have any problem and still good. I checked the EVAP coil it looks clean. I checked the condensing line the water is flowing fine in the pipe. I just checked all wirings and connections found okay. I checked my delta TI got to return air temperature of 70" in supply air temperature of 48. and then I went to the outdoor condenser unit was okay.
Chevy Chase, MD 20815
Dennell H.
Dennell H. Checked in
Plumbing Maintenance Vito VIP 06/10/2024 Upon arrival of home I performed a full plumbing inspections. found no failures, all checklists and notes in system, thank you for choosing vito!
Chevy Chase, MD 20815
Carlos  D.
Carlos D. Checked in
Plumbing Checkup 06/07/2024 arrived on site for a plumbing inspection started by flushing heater while flushing inspected all plumbing in the house tested house pressure and was at 65psi water heater was just installed 3 months ago so it's a new heater tested water quality and have a ph level of 6.4 and a chlorine level of 0.6 and as of today inspection found no issues in the plumbing system all vlaves turn and hold we t back to basement and let the heater flush for awhile longer then wrapped hose up thank you for choosing Vito.
Chevy Chase, MD 20815
Aaron W.
Aaron W. Checked in
AC Maintenance 06/05/2024 Today, I arrived on site for a cooling maintenance job. Here is a summary of the recommended repairs, replacements, and additional services: Furnace: Inspected furnace blower housing. Replaced the filter provided by the owner. Condensate pump is cycling properly. AC Unit: Checked the AC unit. Found a badly rusty fan motor. Heard a buzzing noise coming from the unit. Compressor amps are at 7.7, which is within the normal range. Discovered a dead mouse house next to the contactor. The 2 pole contactor is vibrating badly and needs replacement. The unit is from 1995 and I recommend replacing the full system. The system is equipped with a turbo capacitor. Temperature Split: The temperature split is 20, which is within the acceptable range. Please let me know if you have any questions or if you would like to proceed with the recommended repairs and replacements.
Chevy Chase, MD 20815
Aaron W.
Aaron W. Checked in
AC Maintenance 06/05/2024 Today, I arrived on site for a cooling maintenance job. Here's a summary of the work I completed: Replacements: Replaced 2 filters (16x25x1) provided by the owner. Recommended Repairs: The fan motor is dirty and should be pulled and cleaned. Additional Service: Noted that the flex gas line into the furnace housing is not allowed. The owner is already aware and has placed a paper under the flex line to prevent it from rubbing against the furnace housing. Outdoor Unit Check: Checked the outdoor unit and found that the capacitor and contractor are within specifications with no burn marks. Washed the coil with water. Checked pressures and observed that the temperature split changed to 17. Future Plans: Will check the system again next season before adding a charge to the AC system. Overall, the cooling maintenance was completed successfully, and the system is now in good working condition.
Chevy Chase, MD 20815
Bobby I.
Bobby I. Checked in
06/03/2024 Examined area of concern by customer. Kitchen sink has standing water in it. Customer states drain has been clogged all weekend. Gave customer investment option of 601 to restore flow in area. Removed trap undersink and drained basin. Ran total of 20ft of drain cables through drainline to restore flow in area. Felt obstruction at approximately 12-15ft feet. Pulled cables back to reveal black gunk, indicating liquid drain cleaner has been used in building. Do not know how far customer responsibility of drainline is. Recommend customer communicate with building personnel regarding responsibility. Reassembled drainline and began running water. No backups. Filled basin and drained. Documented. Flow is fully restored in area at this time. Thank you for choosing Vito!
Chevy Chase, MD 20815
Andrew  B.
Andrew B. Checked in
HVAC Call Air Conditioning Spring Tuneup: I arrived at my customer home on 06/04/24 for a one system Ac maintenance outdoor temperature is 76 degrees at this time customer like his/her thermostat set between 65/80 degrees in the home customer provided all air filters I flush the indoor drain and check all amps and components indoor and outdoor indoor coil rust on the edge, coil drain pan rusted out, blower fan motor drawing 6.8 amps, blower fan motor needed to be clean, indoor coil needed to be clean, wet switch not working, no ez trap, drain pan rusted out, system very low on R22, contactor burn Pitt, outdoor coil needed to be clean, ac system not working properly i recommend a replacement of the full system Ac only.
Chevy Chase, MD 20815
Danny  W.
Danny W. Checked in
AC Maintenance Two HVAC Units 06/03/2024 SPRING CHECK BOTTOM FLOOR UNIT #1 Checked filter 16x20x1, checked and chemically cleaned evaporator coil, checked indoor blower motor and wheel, flushed checked and cleaned condensate pan line and ez trap, checked all water safeties, checked temperature split return air temperature 76 , checked supply air temperature 51 , checked condenser motor and coil, checked capacitor ok checked contractor needs replacing soon , checked all electrical wires and connections, checked freon level liquid line temperature 78 , suction line temperature 40 , outdoor air temperature 77 , discharge air temperature 93 CARRIER MODEL NUMBER 38TR024300 SERIAL NUMBER 0393E10614 SPRING CHECK TOP FLOOR UNIT #2 checked and replaced filter 20x20x1, checked indoor blower motor and wheel, checked condensate pan line and trap, added condensate tablets, checked all water safeties, checked temperature split return air temperature 75 , supply air temperature 55 , checke
Chevy Chase, MD 20815
Bobby I.
Bobby I. Checked in
Plumbing Call for Clogged Drain Multi Family Housing Apartment: 06/03/2024 Examined area of concern by customer. Kitchen sink has standing water in it. Customer states drain has been clogged all weekend. Gave customer investment option of 601 to restore flow in area. Removed trap undersink and drained basin. Ran total of 20ft of drain cables through drainline to restore flow in area. Felt obstruction at approximately 12-15ft feet. Pulled cables back to reveal black gunk, indicating liquid drain cleaner has been used in building. Do not know how far customer responsibility of drainline is. Recommend customer communicate with building personnel regarding responsibility. Reassembled drainline and began running water. No backups. Filled basin and drained. Documented. Flow is fully restored in area at this time. Thank you for choosing Vito!
Chevy Chase, MD 20815
Andrew  B.
Andrew B. Checked in
Three-Zone Air Conditioning Maintenance: I arrived at my customer home on 05/29/24 at 9:00am for a three systems Ac maintenance outdoor temperature is 70 degrees at this time customer like his/her thermostat set at 68/75 degrees in the home I adjusted customer thermostat five degrees below the room temperature in AC mode customer provided air filters I flushed all drain pipes and 115v pump check all amps and components indoor and outdoor = Attic carrier heat pump system - Air handler 240v power input,15kw electric element , blower fan motor drawing 3.8 amps, 24v ez trap, 24v wet switch, 240v to 24v air handler transformer, control board, indoor control wires,indoor coil need to be clean, zone control board, drain pan rust, indoor coil rust on the edges, outdoor 240v power input drawing 14.6 amps, compressor drawing 10.7 amps, outdoor fan motor drawing 0.5 amps, 45+5uf dual capacitor reading 40uf, 240v contactor, outdoor control board, outdoor control wires, supply temperature 54.6 degr
Chevy Chase, MD 20815
Leon T.
Leon T. Checked in
No Air Conditioner Call: Compressor damage replace the compressor Our company will send a supervisor to give the price to replace the outdoor unit.
Chevy Chase, MD 20815
Bobby I.
Bobby I. Checked in
Call for Leak Under Kitchen Sink with Rusty Valve: Examined area of concern by customer. Customer has dishwasher technician onsite and since he left there has been a leak under kitchen sink. Inspected undersink and identified leak from disposal unit where dishwasher discharge connects. Gave customer investment option to replace disposal unit. Customer states there is nothing wrong with disposal unit. Made customer aware she needs to call dishwasher technician. Hot side stop is recessed inside wall and customer cannot shutoff. Technician couldn't either. When I tried, sheet metal cut my finger. Ripped sheet metal off wall to access stop and turned with no issue. Demonstrated to customer for future references. Thank you for choosing Vito!
Chevy Chase, MD 20815
Andrew  B.
Andrew B. Checked in
Air Conditioning Check up: I arrived at my customer home on 05/24/24 for a two systems Ac maintenance outdoor temperature is 70 degrees at this time customer like his/her thermostat set between 65/80 I adjusted customer thermostat five degrees below the room temperature in AC mode customer will remove and replace all air filters do not have any at this time I flush all indoor drain pipe and pump check all amps and components indoor and outdoor both systems working at this time not cooling properly systems very low on R22 I recommend a replacement of both systems age 2004 and 2005.
Chevy Chase, MD 20815
Leon T.
Leon T. Checked in
NO AC call: The fan was running but it was not cooling. I checked the indoor unit all safeties all wiring okay. I checked the outdoor unit found not running. the contactor was pushed in but no receiving 240v I checked the wirings and connections at the disconnect and found some loose connections. I also checked the capacitor reading low on capacitance. I tightened everything back up and replaced capacitor. I checked the unit it is running and cooling as of now.
Chevy Chase, MD 20815
Leon T.
Leon T. Checked in
Call for No Air Conditioning in NW DC: Found ac system no running due to a bad capacitor. Advised customer of findings, also noticed contactor was in very poor conditions and no longer reliable. Advised customer of systems age (15 years old) Quoted current repair cost and Recommend considering replacing system. Customer opted to repair system today. replaced contactor and capacitor. Tested system. Operating ok for now but older unit may not be as reliable.
Chevy Chase, MD 20815
Andrew  B.
Andrew B. Checked in
Call for No AC: Upon arrival both systems not working I did a full system check and find no bleeding valve on all of the systems age 2001 customer will like to replace all four
Chevy Chase, MD 20815
Dennell H.
Dennell H. Checked in
Leak Search: Upon arrival of home I noticed that the water in the basement had been removed from the home. I then restore water to home via outside shut off valve and found the leak immediately. the leak has come from a split hose to the washer machine. I explained to the customer that I could replace the washer machine hoses. customer does not want washer machine hoses replaced. customer only wants shut off valves to washer machine shut off. Mr Leon plans to sell the house as is soon and does not want any work done unless it is a emergency. Thank you for choosing Vito!
Chevy Chase, MD 20815
Dennell H.
Dennell H. Checked in
Responded to Call for Broken Pipe and Basement Leak: Upon arrival, customer has a burst pipe or split hose in basement that caused massive flooding in basement. customer wanted me to call insurance company because that he has dealt with in the past and they are is coming today to remove water . The customer will call back tomorrow to have issue rectified and water restored. wssc currently shut off water .
Chevy Chase, MD 20815
Jim V.
Jim V. Checked in
HVAC Maintenace Check in Chevy Chase MD, Lennox Heating & Cooling System - I checked the filter then I replaced dirty filters. I checked the indoor blower and also checked the indoor wheel compartment for any construction and found none. I then checked the blower capacitor, which was problem-free, and I then checked the Evaporator coil and it looks clean. I checked the condensing line and confirmed that the water is flowing fine in the pipe. I also checked all wirings and connections on the Lennox unit and found to be okay. I checked my delta TI got to return air temperature of 49.9" in supply air temperature of 68.8 which is in line and I then went to the outdoor condenser unit, which was also okay.
Chevy Chase, MD 20815
Trusted Quality & Service
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 301-315-6100 .

By pressing Submit I agree to receive phone, email, or text messages from Vito Services to the provided mobile number and also agree to the Vito Services terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next