At Vito Services in ViennaVA, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Vienna’s most capable hands, and let us improve your living standards because you’re entitled to the best.

We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the ViennaVA community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!

Recent Jobs and Reviews in Vienna, VA

Job Locations and Reviews

Jim V.
Jim V. Checked in
performed maintenance on 2 carrier unit basement system is good physical and operational conditions all safeties and controls tested within specs refrigerant levels tested within spec no loose or damaged wiring attic unit notice error code for system freezing notice evap coil was freezing up inspect unit notice system is low on 410a refrigerant talked with regarding fixing or replacing system sent over quote for replacement thank you for your business
Vienna, VA 22182
Danny V.
Danny V. Checked in
09/05/2024 AC MAINTENANCE ON TWO UNITS. (BOTH UNITS LESS THAN A YEAR) #1 Attic Space I checked filter and replaced with one costumer provided. I checked the indoor blower wheel motor housing compartment and found okay. I also checked blower amps and found within manufacturer recommended. I checked the evaporator coil and found okay I checked the ez trap switch on Condensate drain line and found working I flushed drain line with two gallons of water and found draining properly as of now. I checked every other limits and safety and all wiring and connections found okay. I got a return air temperature of 72 and a supply air temperature of 51. I checked the UV light and found working properly. I checked outdoor coil and found dirty and in need of a chemical cleaning. I checked the outdoor temperature of 76 and a discharge temperature of 89 I checked all components outside working within specs. Suction line temperature 54 liquid line temperature 69 This unit is running and cooling a
Vienna, VA 22182
Leon T.
Leon T. Checked in
09/03/2024 performed ac repair found unit low on 410a and capacitor failed added 4lbs of 410 and replaced Cap supply 53 return 72 compressor 6.0 amp fan .07 subcool 13 super heat 10 system is operational thank you for your business
Vienna, VA 22180
Danny V.
Danny V. Checked in
08/28/2024 AC MAINTENANCE ON TWO UNITS #1 Attic lvl I checked filter and found okay client replaced upon today's arrival. I checked indoor blower wheel motor housing compartment for any obstructions and found okay. I checked indoor evaporator coil and noticed a FUNGLE outbreak cultivating within the unit. I flushed condensate line that holds Safe T switch with a gallon of water and found okay. I checked all limits and safetys all wiring and connections found okay. I got a return air temperature of 80 and a supply air temperature of 60 I checked outdoor condenser coil and hosed down with water for client. I checked out door temperature and got 89 discharge temperature is 99 I checked 45/5 capacitor and found within working range. I checked single pole contactor and found okay. This unit is running and cooling as of now. Recommendations: I would recommend adding an air scrubber to the unit due to the cultivation of fungle spours contaminating the unit and circulating back into the
Vienna, VA 22180
Carlos  D.
Carlos D. Checked in
Plumbing Maintenance 08/28/2024 arrived on site for a plumbing inspection started by flushing heater while flushing inspected all plumbing in the house tested house pressure and is at 60psi which is good water pressure to have and means prv works as of today visit found 2 issues in the kids bathroom flapper seems to be looks old and chain is tight making it hard to flush and in master bathroom fill valves hums while filling brought these to customer attention but said she will talk it over with her husband went back to heater and let flushed for awhile longer then wrapped hose up thank you for choosing Vito.
Vienna, VA 22180
Danny  W.
Danny W. Checked in
AC Maintenance 07/30/2024 SUMMER CHECK ATTIC UNIT #2 checked filter 16x25x1, checked indoor blower motor and wheel, checked condensate pan line and trap, checked 1 water safeties in emergency catch pan , no ez trap safety switch. added condensate tablets, checked temperature split return air temperature 74 supply air temperature 52 , checked supply duct found some of the insulation is starting to come apart the glue on the tape has worn off, checked condenser motor and coil, checked capacitor and contactor, checked all electrical wires and connections, found no surge protector, outdoor air temperature 79 , discharge air temperature 93 , checked freon level liquid line temperature 88 , suction line temperature 65 LENNOX MODEL NUMBER 13ACX-042-230-12 SERIAL NUMBER 1911M16464
Vienna, VA 22182
Anthony V.
Anthony V. Checked in
Commercial Plumbing Call Jetting Roof Stacks 06/24/2024 arrived on site to jet the roof stack lines for maintenance, ran the hose up the side of the building and staged the jet, ran the jet down 7 stacks across the roof, had to stop on the last stack early because a leak was found, 10 ft section of 4" cast iron in the ceiling of the ground floor in room G100, reeled the jet back up and dumped the water, cleaned up work area and left
Vienna, VA 22182
Danny  W.
Danny W. Checked in
AC Maintenance 06/19/2024 SPRING CHECK TOP FLOOR UNIT checked filter 20x20x1, checked indoor blower motor and wheel, checked condensate pan, line, and trap with no safety, added condensate tablets, Checked emergency catch pan float switch, checked temperature split return air temperature 77 , supply air temperature 55 , checked condenser motor, removed vines off condenser coil checked coil, checked capacitor and contactor, checked all electrical wires and connections, checked outdoor air temperature 92 checked discharge air temperature 112 , checked freon level liquid line temperature 96 suction line temperature 62 , LENNOX MODEL NUMBER HS26-042-2P SERIAL NUMBER 5899F 40535
Vienna, VA 22182
Anthony V.
Anthony V. Checked in
Commercial Plumbing Call Floor Drain (Storm Water) Clog & Floor Drain Clog 06/07/2024 I arrived onsite. 2 separate clogged floors drains - PVC floor sink in unit G60 (vacant restaurant on ground level) and CI condensate drain in mechanical room across from hair salon on 1st floor. started with floor sink. used wet vac to remove waste from top to be able to see drain. snaked approximately 40 feet with K-50 and hit blockage at 37 feet. worked cables back and forth once clog was reached. pulled back paper towels likely from public restroom. filled up bucket with water and tested drain. floor sink was still backed up so I snaked it again with K-50 and went 45 feet. pulled back more paper towels. poured buckets of water down drain to test for proper drainage. cleaned up work area. next, went to condensate drain on 1st floor. snaked approximately 25 feet with K-50 and encountered blockage at 20 feet. tested drain for proper drainage. cleaned up work area.
Vienna, VA 22182
George  V.
George V. Checked in
Commercial Plumbing Call for Main Drain Line Leak 06/04/2024 I arrived at my customer home on 06/04/24 for the outdoor fan cycling on and off I did a full system check and find the 240v 1/2 p contactor burn Pitt I clean sum off system working at this time need to replace the contactor.
Vienna, VA 22182
Trusted Quality & Service
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 301-315-6100 .

By pressing Submit I agree to receive phone, email, or text messages from Vito Services to the provided mobile number and also agree to the Vito Services terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next