Dependable HVAC & Plumbing Services In Sterling VA
At Vito Services in SterlingVA, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Sterling’s most capable hands, and let us improve your living standards because you’re entitled to the best.
We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the SterlingVA community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!
Recent Jobs and Reviews in Sterling, VA
Our Local Reviews by City
- Adelphi, MD (3)
- Alexandria, VA (4)
- Arlington, VA (2)
- Ashburn, VA (1)
- Aspen Hill, MD (1)
- Berwyn Heights, MD (1)
- Bethesda, MD (24)
- Bowie, MD (1)
- Boyds, MD (1)
- Burke, VA (1)
- Centreville, VA (3)
- Chantilly, VA (2)
- Chevy Chase, MD (7)
- Clarksburg, MD (1)
- College Park, MD (1)
- Damascus, MD (1)
- Derwood, MD (1)
- Fairfax, VA (12)
- Fairfax Station, VA (3)
- Fort Washington, MD (2)
- Frederick, MD (1)
- Gaithersburg, MD (10)
- Germantown, MD (4)
- Great Falls, VA (1)
- Haymarket, VA (10)
- Herndon, VA (7)
- Hyattsville, MD (2)
- Kensington, MD (1)
- Laytonsville, MD (1)
- McLean, VA (1)
- Montgomery Village, MD (1)
- North Bethesda, MD (3)
- North Potomac, MD (1)
- Oakton, VA (1)
- Olney, MD (6)
- Poolesville, MD (1)
- Potomac, MD (11)
- Reston, VA (2)
- Rockville, MD (16)
- Silver Spring, MD (27)
- Springfield, VA (1)
- Sterling, VA (1)
- Takoma Park, MD (1)
- Upper Marlboro, MD (1)
- Vienna, VA (2)
- Washington, DC (66)
Job Locations and Reviews
FALL MAINTENANCE ON TWO UNITS #1 Main unit 90% Gas furnace. This is a older unit. I checked and replaced filter with one Costumer provided. I checked indoor blower motor and 10mfd capacitor and found within specs. I checked the inducer draft motor and flue vent pipe found okay. I checked all wiring and connections and all limits and safetys found okay.i got a return air temperature of 70 and a supply air temperature of 135. I performed a combustion analyze test and got a reading of 50ppm. I checked flame sensor and ignitior found ok. I checked Condensate trap and condensate pump and flushed with a gallon of water and added Condensate tablets. I checked EVAP coil and found clogged with dirt and debris. Overall system is running and heating. In the near future I recommend clients start thinking about upgrading unit. Recommendations for unit #1: Clean coil $362.00 #1 Unit in the garage. Heat pump I checked the filter and replaced with one costumer provided. I checked electr
FALL MAINTENANCE ON ONE UNIT. 2010 Carrier 80% GAS FURNACE. i checked the filter and found it had been replaced upon today's arrival. I went to home Depot to buy a #35 humidifier water panal per nolan. I replaced water panel. I checked the indoor blower wheel motor housing compartment for any obstructions and found none. i checked motor amps and found okay. I checked the inducer draft motor and flue vent pipe and found ok. I checked inducer amps and found within specs. I checked and cleaned burners and heat exchanger. I checked flame sensor and ignitior and found both none reliabile anymore. I checked all wiring and connections and all limits and safetys found okay. I got a return air temperature of 70 and a supply air temperature of 130. Over all unit is running and heating as of now. Recommendations after today's visit: Replace flame sensor $300.00 Replace Ignitor $400.00 The client has agreed to do additional work. I replaced flame sensor and ignitior today and will c
FALL MAINTENANCE ON ONE UNIT 2017 CARRIER 80% GAS FURNACE I checked the filter and replaced with one costumer provided. I checked the indoor blower wheel motor housing compartment for any obstructions and found none. I noticed that the variable speed motor is exposed to any high voltage power surges due to not containing a surge protector. I checked motor amps and found within specs. I checked the inducer draft motor and flue vent pipe and found okay. Inducer amps are within specs. I checked and cleaned burners and heat exchanger. I checked the Ignitor and appears to have been replaced about a year or two ago and in great condition. I checked the flame sensor and found wear and tear on it making it no longer reliable. I checked all limits and safetys. All wiring and connections found okay. I checked humidifier and found working as of now. I replaced #35 hum pad with one Costumer provided. I got a return air temperature of 70 and a supply air temperature of 130. I looked around the ex
upon arrival of home I performed a plumbing inspection found a bad sump pump. price to replace is $1072 customer will call if he wants to replace
FALL MAINTENANCE ON TWO UNITS I checked filters for both units and replaced with one costumer provided. I checked full operation of unit. On low heat and high heat. Temperatures are great. Parts are reliable. All wiring and connections ok all limits and safetys ok. Amps are within specs. Both units have a ECM motor with no surge protection. As of right now the motors are exposed to any high voltage power surges. Overall units are running okay for now. Recommendations: Add Ecm surge protector $309.00x2
Fall Maintenance: i inspected 2016 carrier 80 gas furnace. I cleaned flame sensor. homeowner will purchase and replace 20x25x1 as well as 35 humidifier pad. I checked ignitor 46. inducer amps 1.2 blower amps 2.7. return 71 supply 133. I also completed combustion analysis stack temp is 348,oxygen 7.3, 66 ppm. system is heating properly at this time thank you for choosing vito services.
Performed maintenance on 2010 80% furnace/AC. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found fan is slightly dirty. Water panel in humidifier needs to be changed. Filter is clean. Performed combustion analyzer test and found system has high readings for C02 at 80-84 ppm. The system is starting to be unsafe. Recommended replacing system because of age and condition of system. Full Furnace and AC is $13,000+ depending on the system
Call to do maintenance on 2023 heat pump. During maintenance checked all components for proper operation found no issues with components. Checked for loose wires and any dirt. Filter does need to be changed. System is clean and all wires are connected properly. Recommended customer add humidifier to help with make home more comfortable. $1300
Call to do maintenance on 2024 Heat pump/ Furnace. During inspection found system is in great condition and still new. Cycled system completely at this time systems components are all working properly and are clean. At this time system is fully operational.
change furnace AC and coil. run new vinyl tube for new condensate pump
HVAC Error Code: Upon arrival customer concerns system is giving low pressure code. Checked system found 2017 90% furnace inducer motor is have a hard time because of water back up. Drained port and cycled system at this time system is full operational. Thank you for choosing vito
Performed maintenance on 2017 Heat pump. during inspection found inside of system is dirty and needs to be cleaned. There is a fungus cultivating inside of system and blower wheel is dirty. check condenser unit and found all components are in working order but condenser coil needs to be cleaned. informed customer of find and recommended signing up for membership to cover future maintenance and discount on prices. Customer informed me that they were on the garneski monthly membership plan and that we would honor the maintenance contract. informed customer if this is the case we would waive the cost today. Customer does want to sign up for monthly maintenance plan. At this time system is operational. Please give customer a call. Recommendations Duct Cleaning $897 Blower and Conditioner Cleaning $600 Air scrubber $1100 Membership $17.50 (monthly) $244 (yearly)
NO HEAT 80% Gas furnace NO AC Both units are passed its life expectancy Called for heat at Mercury thermostat and nothing kicked on. I reset the board and inducer motor came on. Ignitor came on and flames did as well. Flames ran for about five seconds and turned off. The unit kept on short cycling. While the unit did run the flames showed concerns. The flue vent pipe has signs of backdraft. And the heat exchanger seems to have been compromised. The AC has not been working since last visit from garneski. I will talk to whoever is in charge at I will recommend them to replace the full system. The furnace is unsafe to be used at this point. I will pass this lead on to Moe and provide pictures and measurements of unit to get quote on a full system. FURNACE: HEIGHT 33' WIDTH 17 1/2' LENGTH 28' AC COIL: HEIGHT 26' WIDTH 17 1/2' LENGTH 22' SUPPLY: WIDTH 18' LENGTH 20' Dispatch fee $120.00
performed fall checkup on two units first unit was a gas furnace downstairs in the basement found everything within specs all wiring and connections all limits and safety is okay temperature rise is within recommendation all amperages are within specs. I didn't notice in the furnace the cultivation of fungus. there's a 75 gallon hot water heater downstairs in the basement over 15 years has no expansion tank and there is noticeable backdraft this hot water heater needs to be replaced. I check heat pump in the Attic found over its life expectancy at 15 years there's a whole bunch of fungal growth cultivating within the unit there's a lot of rust on the coil this unit is no longer reliable and recommended to be replaced as well. one air scrubber to each system would also be recommended to keep the unit clean and purify the air. I have passed this on to mow he is working on getting a proposal to the client for a water heater and a new air handler and outdoor unit for the Attic. REPLACE
Performed HVAC Maintenance on 2023 AC\Furnace. Found no issues with system at this time. changed filter and confirmed operations of air scrubber. final cycled system at this time system is fully operational. recommended Ecm surge protector. ECM Surge protector $198
HEAT MAINTENANCE ON ONE UNIT: I Performed maintenance on 2012 AH/HP. found interior of system in good condition. all components amping normally. and working properly. blower wheel is slightly dirty. Electric element okay. i checked outside unit found starting components are starting to fail. capacitor is reading below 5% meaning is going togo. found contactor has normal wear and tear from usage and is also starting to fail. will throwing condensor cleaning to help with dirt built up on coil. I got a return air temperature of 70 and I got a supply air temperature of 120 Option#1 Capacitor, contactor and condenser clean $992 Option#2 Capacitor and contactor $610 Option#3 Capacitor $320 Client decided to not go ahead with recommendations, office will need to follow up with client. Thank you for choosing VITO SERVICES.
Arrived on site for heating maintenance. Found condensate line dirty; brushed drain and added vinegar for cleaning. Inspected heat exchanger, flue, and furnace flue; all in good standing. Checked blower capacitor; measured at 9.2 on a 10 mfd, indicating its starting to get low but still functioning well. Inducer capacitor is within specifications. Inducer amps .33 Ignitor measured at 53, which is also within specifications. Flame sensor is clean. Blower wheel and housing are in good condition. No rusting or condensating leak. 0ppm Co in space. Humidifier clean at this time. Confirmed that the furnace is heating properly at this time.
HVAC Call: performed maintenance on carrier Infiniti furnace system is good physical and operational conditions humidifier operational and UV all safeties and controls tested within spec thank you for your business
FALL MAINTENANCE ON ONE UNIT. Carrier 80% Gas furnace 88k BTU 2YRS I checked the indoor blower wheel motor housing compartment for any obstructions and found none I checked the indoor blower wheel motor amps and found within specs I checked the inducer draft motor and flu vent pipe found okay I checked inducer amps found within recommended specs. I checked the igniter ohms found okay I checked flame sensor clean found okay. I clean burners I checked heat exchanger and found it okay. I checked all limits all safeties all wirings and connections found okay at this time. I got to return air temperature of 76 and a supply air temperature of 130. I replace the UV bulb that the customer provided the old one was burnt out. this bulb should last for the next two years. the unit is running and heating as of now there is no recommendations at this time if there is any further questions or concerns please give us a call. Thank you for choosing VITO SERVICES.
09/11/2024 performed maintenance on 10 years old carrier gas furnace inspect operational of system, notice ignitor needs to be replaced all other electrical and safeties tested within spec also noticed humidifier need a new pad option 1 replacement of ignitor and water panel 684 option 2 replacement of ignitor 484 thank you for your business
09/05/2024 notice outdoor unit not operational found capacitor failed and system slightly low on charge after homeowners approval replaced capacitor and add need refrigerant 107/240 subcool 12 super heat 8 thank you for your business
performed ac maintenance 16 year old heat pump notice unit needs full system clean for both evap coil ,cond coil and blower wheel also noticed system is low on R22 talk with homeowners regarding replacing unit thank you for your business
Commercial Plumbing Call Leak Search 07/18/2024 Cut into the wall but found nothing there, then check the sink, the drains but no leaking. I then went to elevator mechanical room and found moisture it's the AC in the ceiling that is leaking from the conversation line thank you for choosing vito
07/05/2024 Arrived on site to change out an old faucet on the 2nd floor, had to wait for an escort to enter room, once in room removed old faucet, new faucet does not match old faucet but customer does not mind, continued replacing, installed new faucet and tested it, no leaks or problems found, cleaned up work area and left