Dependable HVAC & Plumbing Services In Haymarket VA
At Vito Services in HaymarketVA, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Haymarket’s most capable hands, and let us improve your living standards because you’re entitled to the best.
We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the HaymarketVA community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!
Recent Jobs and Reviews in Haymarket, VA
Our Local Reviews by City
- Adelphi, MD (3)
- Alexandria, VA (4)
- Arlington, VA (2)
- Ashburn, VA (1)
- Aspen Hill, MD (1)
- Berwyn Heights, MD (1)
- Bethesda, MD (24)
- Bowie, MD (1)
- Boyds, MD (1)
- Burke, VA (1)
- Centreville, VA (3)
- Chantilly, VA (2)
- Chevy Chase, MD (7)
- Clarksburg, MD (1)
- College Park, MD (1)
- Damascus, MD (1)
- Derwood, MD (1)
- Fairfax, VA (12)
- Fairfax Station, VA (3)
- Fort Washington, MD (2)
- Frederick, MD (1)
- Gaithersburg, MD (10)
- Germantown, MD (4)
- Great Falls, VA (1)
- Haymarket, VA (10)
- Herndon, VA (7)
- Hyattsville, MD (2)
- Kensington, MD (1)
- Laytonsville, MD (1)
- McLean, VA (1)
- Montgomery Village, MD (1)
- North Bethesda, MD (3)
- North Potomac, MD (1)
- Oakton, VA (1)
- Olney, MD (6)
- Poolesville, MD (1)
- Potomac, MD (11)
- Reston, VA (2)
- Rockville, MD (16)
- Silver Spring, MD (27)
- Springfield, VA (1)
- Sterling, VA (1)
- Takoma Park, MD (1)
- Upper Marlboro, MD (1)
- Vienna, VA (2)
- Washington, DC (66)
Job Locations and Reviews
HVAC Tuneup: Called to do maintenance on 2006 80% Furnace/ 2013 AC. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Checked heat exchanger and found multiple rust and stress cracks near demples. Informed customer of findings and let them know system is not looking good because of age of system. Performed combustion analyzer test and found system is over safety limit for carbon monoxide being produced. Limit is 100ppm system was reading at 200ppm. Informed customer of findings and shutdown furnace via gas. System is a safety hazard and can cause serious harm to occupants in home. By law we are required to shutdown system if it is a safety hazard.
HEAT MAINTENANCE ON TWO UNITS. #1 Basement/1st Floor HEAT PUMP: I checked the filter and found it has already been replaced upon today's arrival. I checked the indoor blower wheel motor housing compartment for any obstructions and found none. I checked motor amps and found within specs. I checked all wiring and connections and all limits and safetys working properly. i checked electrical heater element and found okay. i checked EVAP coil found okay. I checked the Aerus air scrubber found okay and working as of now. i checked the EZ trap safety switch and condensate pump and tested it with about half gallon of water and found okay. i got a return air temp of 71 and a supply air temperature of 114. i checked the outdoor condenser coil and found ok I checked outdoor temperature and discharge temperature found okay. liquid line temperature and suction line temperature found okay. I checked inverter board and found okay. All components outside and reliable. Indoor breaker for unit has a
Returned to install flame sensor and ignitior for main unit. Checked operation and all okay. Will collect remaining balance. If there's any issues or concerns please feel free to give us a call. Thank you for choosing VITO SERVICES.
arrived on site to do an inspection for room 407, was shown all fixtures including 4 sinks, 2 toilets, and 2 showers, water heater is communal, shut off all sinks to test the valve, all held as they should, tested the drains of all fixtures by draining a large amount of water, no issues draining, all toilets are functional with no issues, tub and shower faucets working as intended, garbage disposal has no issues, customer has no additional concerns, cleaned up work area and left
FALL MAINTENANCE ON TWO UNITS (BOTH FURNACE ARE IN THE ATTIC) #1 Main lvl unit. The filter had been replaced upon today's arrival. I checked the indoor blower wheel motor housing compartment for any obstructions and found none I checked the 7.5mfd capacitor and found okay. I checked the inducer draft motor and flue vent pipe and found okay. Inducer amps okay. I checked and cleaned burners and heat exchanger. I checked the flame sensor and found worn out and no longer reliable. I checked the Ignitor and noticed white spots on it indicating it is brittle. I checked all limits and safety and all wiring and connections found okay. I got a return air temperature of 80 and a supply air temperature of 133. This unit is running and heating as of now. Recommendation for unit #1 Replaced flame sensor $374.00 Replace Ignitor $570.00 Total $944.00 #2 Top lvl unit The filters had also been replaced upon today's arrival. I checked the indoor blower wheel housing compartment for any ob
FALL MAINTENANCE ON ONE UNIT 2017 80% GAS FURNACE I checked the 20254 and found clogged, the client will purchase more and replace this will need to be done ASAP. I checked the ECM motor and found it is exposed to any high voltage power surges due to not having a surge protector on it. I checked blower amps and found okay. I checked the inducer draft motor and flue vent pipe and found okay. inducer amps are okay. I checked and cleaned burners and heat exchanger. I checked the Ignitor reading 50ohms. I checked the flame sensor and noticed wear and tear on it making it no longer reliable. I checked all limits and safetys all wiring and connections found okay. I checked the humidifier and humidifier panal found needs to be replaced. I got a return air temperature of 73 and a supply air temperature of 138. Today's visit $120.00 Recommendations after today's visit: Replace flame sensor $379.00 Add Ecm surge protector $309.00 water panal $206.00 The client did not make a decisio
I arrived at my customer home for a one system heat maintenance outdoor temperature is 55 at this time customer like his thermostat set between 65 and 80 in the home I adjust customer thermostat 5 above the room temperature in heat mode customer provided all air filters I checked all amp and components and found indoor gas furnace will run for 5 minutes overheat shut down and start up I did a combustion test systems reading 18 PPM customer asks for a price for replacement I provide pricing and proposal for replacement of the gas furnace customer getting a second proposal and will let me know by Wednesday systems working at this time.
HVAC Maintenance Check: did a fall check up and ran equipment and checked for proper operation did amp draws on blower motors and checked caps and everything checked out fine but did make recommendations for expansion tank to have strap installed on it to bring it up to code. also made a note that blower motor on indoor unit required 5 amp draws and I was getting 8
I arrived today to replace two Contractors. One contactor was for the outdoor heat pump which was a single pole Contactor. The second one was for the air handler electrical heater element double pole Contactor. I checked operation after replacing parts and found okay with no issues at this time. I will collect the balance of $523.00 Thank you for choosing VITO SERVICES.
customer informed us that they would like an plumbing inspection done at their residence. once on site I contacted the customer and began inspection. started in the bathroom where the water heater and groundfos pump is and worked how way up through the house. flushed water heater . after flushing the water heater we then started ton inspect every faucet and bathroom in the home. recommended replacing two faucets and and 4 supply lines customer with an explanation. pack up equipment and left job
Thank you, Robert!
Call to do maintenance on 3 system. Checked attic system first. System is a 2017 communicating 80% Furnace/AC. Checked all components for proper operation found no issues with components. Checked for loose wires and any dirt. Found blower is dirty and needs to be cleaned. Changed all filters final cycled system at this time system is operational. Checked sunroom system next. 2023 Communicating Heat pump. Checked all components for proper operation found no issues with components. Checked for loose wires and any dirt inside system. System is clean and working properly. Changed filter as well. Final cycled system at this time system is operational. Last system supply's main floor. System is a 2017 80% communicating Furnace/AC. During inspection checked all components for proper operation found no issues with components. Checked for loose wires and any dirt. Found system clean and in good condition. Checked Steam humidifier for proper operation and found it is good to go. Filter has b
Call to do maintenance on 2021 90% Furnace/AC. During maintenance checked all components of system. Checked for any loose wiring and cleanliness of system. Found all components are working at this time. System is clean as well. UV bulb is still bright. Humidifier pad needs to be changed along with air filter. Changed air filter and humidifier pad. Final cycled system at this time system is operational. Need to collect $209 for humidifier
Upon arrival customer confirmed 2 units on site. 1st unit is a 2018 LP gas Furnace/AC. During maintenance found system is in good condition but is dirty. All components are amping properly and functioning well. Found Air knight bulb is out and needs to be replaced, also found blower dirty and needs to be cleaned. During maintenance of 2nd system found system is also in working order and is very clean. All components are working and amping properly.
Hi James - Welcome to the Vito Family! We are so glad to hear that you were pleased with our front office and technician and so glad to hear that you'll have us back in your home! Thank you for taking the time to let us know about your experience and for the 5-Star Review!
Upon arrival customer confirmed 2 units on site. 1st unit is a 2018 LP gas Furnace/AC. During maintenance found system is in good condition but is dirty. All components are amping properly and functioning well. Found Air knight bulb is out and needs to be replaced, also found blower dirty and needs to be cleaned. During maintenance of 2nd system found system is also in working order and is very clean. All components are working and amping properly.
Performed maintenance on Aquatherm system. Checked all components for proper functioning and no issues at this time. All components are working properly. Flipped handle on hot water tank to circulation pump. Checked heat rise of system getting 50 rise. Blower is slightly dirty, changed filters and secured any loose wiring. Final cycled system at this time system is fully operational. Thank you for picking Vito
arrived at location for a plumbing inspection, customer came out and informed me that she has cancelled for until Nov 4th
Thank you, Pat!
HVAC Fall Maintenance: I serviced Lennox 90 percent gas furnace. all filters and humidifier clean and set to heat position. I took delta t return 74 supply 149. I took amp reading on all major components and motors. I cleaned dirty flame sensor and checked ignitor ohms 60 ok at this time. gas pressure is at 3.5 w/c. both dampers are open. combustion was completed and 7 percent oxygen. 100 stack temp. 36 ppm. all uv lights are operational at this time.
HVAC Fall Maintenance: I completed heat maintenance on 80 percent gas furnace. I checked all major components and checked for correct amp reading. I took temp splits. I checked all safeties and replace all filters and humidifier pads. I tested and set to 35 percent. I cleaned dirty flame sensor and checked ignitor ohms 49 ok at this time. I also checked combustion Co is 56 ppm. stack temp 226. oxygen 9 percent. system is heating properly at this time. water heater expansion tank is corroded as well as the female fitting and will need to be replaced.
Performed maintenance on 2015 Furnace/AC x2. found systems in decent condition. checked all components and found both systems are operating normally. Found blower is dirty and need to be cleaning on basement unit. not finding any issues with systems at this time. Final cycled both systems at this time systems are operational. Recommendations: Blower clean $340
checked on new unit all limits and safeties within specs all wires and connections found okay all components are okay flame sensor igniter I take all amps on the inducer draft motor and blower wheel motor I check the humidifier humidifier is not in use I checked night UV bulb it has not been changed for 5 years that client does not want to replace bulb at this time I checked the water heaters running leaks found none I checked temperature rods found within specs. at this time there's no recommendation any recommendations to continue with annual maintenance. all pictures are up on Xoi. thank you for choosing vito services.
Hi Laura - We are so glad to hear that you were pleased with Vito's HVAC service. Thank you for taking the time to let us know and for the 5-Star Review!
Performed maintenance on 2021 AC/Furnace. found system to be in good condition. All parts are operational and amping correctly. checked steamed humidifier, found in good condition with new container. At this time system is fully operational. recommended ECM surge protector $189
arrived at location for a customer provided faucet in master bed room, customer bought there own faucet for us to install, the first faucet gave no issues and good in and out, but the second faucet it's p-trap was glued on, advise the customer about it and how it would need too be changed out in order to put the new pop up assembly in, customer agreed and was advised of an up charge as well, replace trap tested for any leaks no leaks occured. went back inside to install old faucet, because the customer had the wrong one which caused the medicine cabinet to not be able to open fully.
FALL HVAC MAINTENANCE CHECK checked and replaced customer supplied filters two 20x20x1 , checked indoor blower motor and wheel, checked inducer draft motor and flue pipe, cleaned and checked burners and heat exchanger, cleaned flame sensor, checked all safeties and limits, checked temperature rise 30-60 return air temperature 75 supply air temperature 125 ,. found no UV light system CARRIER MODEL NUMBER 58STA090-16 SERIAL NUMBER 4503A40298
Thank you so much for this great 5-star review. We really appreciate your business and helping to share the word about us.
Performing Preventative Maintenance Plumbing Check today. Water pressure in home is 65psig. Water Heater is 2yrs old. Flushed water heater directly outside. Minimal buildup removed from tank today. Customer states since she started using deodorizer product in wash machine, sour smell has stopped in laundry area. Kohler Aquapiston toilet handle sticks up when flushing. Inspected area and sprayed handle with WD-40 and exercised. Aquapiston goes up and down properly now. In master bedroom bathroom, connected faucet Pull to control arm undersink to operate stopper. Customer Roman Tub Faucet leaks when used. Signs of leak going inside wall to tub area. Grout is cracking badly. Front wall of tub frame will require removal to perform replacement. Customer would also like tub replaced. Spoke to customer regarding situation and customer states she would like framing preserved. If framing cannot be preserved, she would like tile matched to bathroom to avoid retiling entire bathroom. Kitchen area
FALL HVAC MAINTENANCE CHECK TOP FLOOR SYSTEM checked filter 20x25x4, checked indoor blower motor and wheel, checked inducer draft motor and flue, checked all safeties and limits, cleaned and checked burners and heat exchanger, checked flame sensor, checked uv light system, checked temperature rise 15 -45 , 25-55 return air temperature Air temperature 74 supply air temperature 119 , . CARRIER MODEL NUMBER 58TNOA090C21-20 SERIAL NUMBER 2622A29658