Dependable HVAC & Plumbing Services In Darnestown MD
At Vito Services in DarnestownMD, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Darnestown’s most capable hands, and let us improve your living standards because you’re entitled to the best.
We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the DarnestownMD community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!
Recent Jobs and Reviews in Darnestown, MD
Our Local Reviews by City
- Adelphi, MD (3)
- Aldie, VA (1)
- Alexandria, VA (4)
- Arlington, VA (2)
- Ashburn, VA (4)
- Aspen Hill, MD (2)
- Berwyn Heights, MD (1)
- Bethesda, MD (31)
- Bowie, MD (2)
- Boyds, MD (1)
- Brookeville, MD (1)
- Burke, VA (1)
- Cabin John, MD (1)
- Centreville, VA (3)
- Chantilly, VA (4)
- Chevy Chase, MD (9)
- Clarksburg, MD (1)
- College Park, MD (1)
- Damascus, MD (1)
- Derwood, MD (1)
- Fairfax, VA (14)
- Fairfax Station, VA (3)
- Fort Washington, MD (2)
- Frederick, MD (2)
- Gaithersburg, MD (11)
- Germantown, MD (5)
- Great Falls, VA (1)
- Haymarket, VA (11)
- Herndon, VA (8)
- Hyattsville, MD (3)
- Kensington, MD (2)
- Laytonsville, MD (1)
- McLean, VA (2)
- Montgomery Village, MD (1)
- North Bethesda, MD (3)
- North Potomac, MD (1)
- Oakton, VA (2)
- Olney, MD (7)
- Poolesville, MD (1)
- Potomac, MD (14)
- Potomac Falls, VA (1)
- Reston, VA (3)
- Rockville, MD (20)
- Silver Spring, MD (32)
- Springfield, VA (1)
- Sterling, VA (1)
- Takoma Park, MD (1)
- Upper Marlboro, MD (1)
- Vienna, VA (2)
- Washington, DC (78)
Job Locations and Reviews
07/16/2024 NO AC CALL. Upstairs unit in the attic came on but the outdoor compressor kept shutting on and off. I checked and cleaned the outdoor unit because it was extremely clogged. I than put my gauges on and I got a low side pressure of 150psi and i got a high side pressure of 335psi. While inspecting unit I also checked the capacitor to see if it was low because a low capacitor and dirty coil will end up over heating the compressor causing the unit to kick on and off. The capacitor was low and I replaced it. After I cleaned the coil and replaced the capacitor the unit stayed on for about an hour and I kept an eye on my gauges and the pressure were steady. On the other hand I took my temperatures for my delta T and I got a return air temperature of 83.3 and a supply air temperature of 69.9. I will say to let the unit run to see if it cools down. If it does not cool down by tomorrow morning we will have to return. Thank you for choosing VITO SERVICES. Capacitor $320.00 Coil
Attic Air Conditioner Not Cooling 06/20/2024 Customer states upstairs system struggle to keep up during peak hours of hot weather. System thermostat set to 75 and satisfied. Turned system on and found supply temperature at 65F with return temp of 78. Checked refrigerant and noticed it was slightly low on refrigerant. Advised customer that this could be due to a leak in the system but would have to recharge add dye and leak sealer. Also gave option to simply recharge without the dye but none of this would guarantee a permanent solution. If system goes low again we would have to search for the dye. Customer agreed, I added two pounds of 410A including the pro charge. checked air filters and tested overall system performance and now cooling better ( Supply 59F and return 77F) R-410a Dye, Leak Sealant, and recharge Includes adding of the r-410a dye, refrigerant small leak seal and up to two pounds of refrigerant customer states he was advised to operate this unit at not lower then 75F
Plumbing Call Hot Water Heater Not Working 06/03/2024 Examined area of concern by customer. 75g Atmospheric Water Heater pilot has gone out. Spoke to customer regarding age of water heater and made customer aware I will assess. Lit pilot with no malfunctions and engaged burner assembly. Performed backdraft test and all is negative. B-vent takes exhaust out through roof. Possible gust of wind blew out pilot. Formulated options to replace existing 13yr old water heater. All is operational at this time. Thank you for choosing Vito! NO WARRANTY ON TODAY'S VISIT