Dependable HVAC & Plumbing Services In District Heights MD
At Vito Services in District HeightsMD, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to District Heights’s most capable hands, and let us improve your living standards because you’re entitled to the best.
We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the District HeightsMD community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!
Recent Jobs and Reviews in District Heights, MD
Our Local Reviews by City
- Adelphi, MD (3)
- Alexandria, VA (1)
- Arlington, VA (1)
- Berwyn Heights, MD (1)
- Bethesda, MD (20)
- Bowie, MD (1)
- Burke, VA (1)
- Centreville, VA (2)
- Chantilly, VA (2)
- Chevy Chase, MD (6)
- Damascus, MD (1)
- Fairfax, VA (4)
- Fort Washington, MD (2)
- Frederick, MD (1)
- Gaithersburg, MD (5)
- Germantown, MD (4)
- Great Falls, VA (1)
- Haymarket, VA (5)
- Herndon, VA (6)
- Hyattsville, MD (2)
- Kensington, MD (1)
- Laytonsville, MD (1)
- Montgomery Village, MD (1)
- North Bethesda, MD (3)
- North Potomac, MD (1)
- Oakton, VA (1)
- Olney, MD (3)
- Poolesville, MD (1)
- Potomac, MD (6)
- Reston, VA (2)
- Rockville, MD (14)
- Silver Spring, MD (23)
- Takoma Park, MD (1)
- Washington, DC (49)
Job Locations and Reviews
New Furnance AC Installation: 08/23/2024 removed old furnace and set and installed new furnace and tied everything back in and replaced the flu with all b vent
08/02/2024 I arrived at my customer home to add R22 provided by management I added 2 lb of R22 refrigerant to the system inspect the inside system and find the coil and ductwork needed to be clean AC system working at this time.
T2 Main Line Stoppage 08/01/2024 arrived at location, we went into third floor first and the line was disconnected so we reconnected the line. We moved down to the first floor, there was a partial blockage in the condensate line. Used the K-50 to unclog it. Tested the line with water and it was draining fine. Cleaned our area. Told the contact if it happens again anytime soon, recommended the line be changed.
07/19/2024 NO AC upon arrival the thermostat was set to 71 and the indoor temperature was 80. the unit had water all over it due to unit getting iced up. The furnace and AC are past its life expectancy. The filter was extremely clogged. The repairs to make on this unit to get it up and running will be to replace capacitor on blower wheel motor. Pull and clean blower wheel motor, clean the EVAP and outdoor coil. Flush the condensate line with nitrogen and lastly add Refrigerant. The refrigerant used is r-22. I did advise the resident manager that making the repairs won't be a permanent fix due to its age. More parts can get compromised quickly. I did recommend her to replace the full system. Price for repair Capacitor $380.00 Blower wheel clean $799.00 EVAP coil clean $699.00 Outdoor coil clean $680.00 Flush line with nitrogen $450.00 First pound of R-22 $420.00 Any additional pounds of r-22 $380.00 The other option will be to get a comfort advisor out there to provid
07/19/2024 NO AC The thermostat is set at 75 and the room temperature is reading 75. The tenant said that after the maintenance man came a few days ago it has been working just fine. I checked my temperature split and got a 16 difference. I found the filter extremely clogged and I let the resident manager know that the maintenance man will need to come out and replace filter.
07/19/2024 No AC There was nothing wrong with this unit. The Thermostat was set at 72 and the indoor temperature was 72. !y temperature split was 18 The only issue was the filter that needs to be replaced my maintenance asap.
07/18/2024 NOT COOLING PROPERLY checked furnace filter ok, found has dirty blower wheel, motor been replaced before, dirty evaporator coil needs chemicals to clean, found ducts needs cleaning, checked temperature split got 74 return air temperature, supply air temperature 61 , 13 Delta t need 15 or better , tenant caplained about how hot the furnace room gets, putting insulation on openings will help, checked condensing unit outdoor air temperature 90 , discharge air temperature 118" very high discharge temperature, the outter surface of the coil has been cleaned before, will chemicals and high pressure water hose to clean middle and back of the coil, R 22 system is low on refrigerant GOODMAN MODEL NUMBER CK24-1B SERIAL NUMBER 9407042970
Local AC Call Thermostat Will Not Shut Off: 07/10/2024 Today, I arrived on site to address the following issues with the customer's system: System not turning off: Investigated the system and found that it is not turning off as expected. System not cooling and low pressures: Checked the system and confirmed that it is not cooling properly. Observed low pressures in the system. Temperature split of 5: Noted a temperature split of 5 degrees, indicating a potential issue with the system's cooling efficiency. Oil inside insulation: Discovered oil inside the insulation of the system. Bubble spray test: Conducted a bubble spray test on the joints but did not detect any leaks. Possible low pressures or leak elsewhere: Suspected that the low pressures may be due to a leak elsewhere in the system. Recommended actions: Suggested adding charge to the system to improve cooling performance. Proposed using leak seal to identify and address the source of the leak. System not cooling
07/09/2024 arrived on site to address a stoppage in apartment 1922, issue was not a sewer main but a condensate on the 3rd floor that was backed up and leaking downstairs, took apart the line and snaked the line, snake came back dry, no water in line, determined the issue to be the back grade in the drain pipe to be the cause of the issue, lowered the grade and put it back together, cleaned up work area and left
NEW AC Install 07/05/2024 recovered old refrigerant and removed all the old equipment and set and installed new indoor coil and also set new outdoor unit and tied everything back in from line set to drains and wiring. also installed ez trap on drain line. line charged equipment. went to fire up equipment but was running into high voltage problems. could not start equipment.
NEW HVAC System Installation 06/17/2024 New Goodman A.c and Coil 2 ton. Replaced uncased coil and 2 ton condenser
Installation of New Air Conditioner 06/10/2024 recoved old refrigerant and removed all old ac equipment and set and installed all new ac equipment and tied everything back in and evacuated system and checked for leaks with nitrogen and charged equipment and fired it up to check for proper operation
SPRING CHECK York Air Conditioner Unit: I checked and replaced filter 20x25x1, checked indoor blower motor and wheel ok. checked condensate pan, line , with no trap,ok , no water safeties, checked temperature split return air temperature 80 , supply air temperature, 48, checked condenser motor and coil ok, checked capacitor and contactor ok, checked all electrical wires and connections, checked outdoor air temperature 69 , checked discharge air temperature 82 , checked freon level liquid line temperature 70 , suction line temperature 48 , YORK MODEL NUMBER NA SERIAL NUMBER NA SUN FADED