Dependable HVAC & Plumbing Services In Olney MD
At Vito Services in OlneyMD, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Olney’s most capable hands, and let us improve your living standards because you’re entitled to the best.
We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the OlneyMD community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!
Recent Jobs and Reviews in Olney, MD
Our Local Reviews by City
- Adelphi, MD (3)
- Aldie, VA (1)
- Alexandria, VA (4)
- Arlington, VA (2)
- Ashburn, VA (4)
- Aspen Hill, MD (2)
- Berwyn Heights, MD (1)
- Bethesda, MD (31)
- Bowie, MD (2)
- Boyds, MD (1)
- Brookeville, MD (1)
- Burke, VA (1)
- Cabin John, MD (1)
- Centreville, VA (3)
- Chantilly, VA (4)
- Chevy Chase, MD (9)
- Clarksburg, MD (1)
- College Park, MD (1)
- Damascus, MD (1)
- Derwood, MD (1)
- Fairfax, VA (14)
- Fairfax Station, VA (3)
- Fort Washington, MD (2)
- Frederick, MD (2)
- Gaithersburg, MD (11)
- Germantown, MD (5)
- Great Falls, VA (1)
- Haymarket, VA (11)
- Herndon, VA (8)
- Hyattsville, MD (3)
- Kensington, MD (2)
- Laytonsville, MD (1)
- McLean, VA (2)
- Montgomery Village, MD (1)
- North Bethesda, MD (3)
- North Potomac, MD (1)
- Oakton, VA (2)
- Olney, MD (7)
- Poolesville, MD (1)
- Potomac, MD (14)
- Potomac Falls, VA (1)
- Reston, VA (3)
- Rockville, MD (20)
- Silver Spring, MD (32)
- Springfield, VA (1)
- Sterling, VA (1)
- Takoma Park, MD (1)
- Upper Marlboro, MD (1)
- Vienna, VA (3)
- Washington, DC (78)
Job Locations and Reviews
I serviced 80 percent gas furnace. I cleaned flame sensor. I replaced 14x24x1 filter. return is 72 supply is 128. inducer is pulling .38 amps. blower 3.13. capacitor on blower is reading 4.97/5. I checked all control wiring and tightened connections as well as 24v240 at transformer. I also checked all rollout safety and hight temp switch. ignitor is reading 34 ohms. Co combustion analysis reading 348 stack temp, 11 oxygen and 46 ppm. Gas furnace is heating properly at this time thank you for choosing vito services.
Dryer Vent Cleaning: 1 dryer vent cleaning. a 20' run. No ladder needed. Dryer vent pipe only accessable at the ends.
upon arrival of home I performed a full plumbing inspection checked all drains and toilets for stoppages checked all valves and faucets for leaks. found 17 year old 40 gallon gas heater. recommend customer replaced sooner than later .$2517 water levels are ideal in home
Hi Thelma - We are so glad to hear that you were pleased with Yona's HVAC service. Thank you so much for taking the time to let us know about your experience ... and for the 5-Star Review!
removed old furnace installed new furnace
FALL MAINTENANCE ON ONE UNIT 2008 CARRIED 80% Gas furnace. I checked and replaced 16201 filter and replaced with one Costumer provided. I'm adjusted the gas pressure because the temperature rise was top high. i checked inducer draft motor and found pulling high amps. i checked Ignitor and flame sensor and found worn out and no longer reliable. i checked 10mfd capacitor and found low on capacitance. I performed a combustion analyze test and got a reading over 100ppm making unit unsafe to run. I did advise client. I RECOMMEND THE REPLACEMENT OF 2008 FURNACE. Original furnace is 132,000 BTU will replace with 110,000 BTU Furnace size Height: 33 1/2 inch tall Width: 21 inch Depth : 24 inch Return drop is 14x20 Carrier furnace availability final price $7529.00 Including 10% discount and $300 coupon off. 2 year labor warranty. The costumer has agreed to go ahead and move on with getting the furnace. We will provide 3 space heaters for costumer. Client will pay full amount of
Hi Linda - We are so glad to hear that you were pleased with Aaron's HVAC service ... thank you for letting us know and for the 5-Star Review!
Today, I arrived on site for heating maintenance on the Carrier furnace. Observed that the secondary safety switch is loose and requires adjustment. Noticed that the secondary safety is glued and needs to be cut and replaced for proper function. Detected condensation from the furnace exhaust, with moisture present on the outside of the furnace ducts. Suspected an obstruction in the flue or improper installation of the chimney cap, leading to backdraft issues. Confirmed that the flame sensor is clean and the ignitor ohms are within the acceptable range. Recommended installation of a surge protector on the blower motor to safeguard against power surges. Replaced the filter provided by the owner. Suggested a dedicated transformer for the UV light installation. Found that the chimney cap is missing and requires repairs to prevent further damage to the system.
Hi Thelma - Thank you for the 5-Star Review!
Toilet Needs Repair: upon arrival of home I noticed that the master bath toilet was running constantly . with the customer consent I performed a minor toilet rebuild. checked all connections for leaks and found no failures.
upon arrival of home I performed a plumbing inspection checked all drains and toilets checked all valves and faucets checked all plumbing components and found no failures. checked the 50 gallon gas heater and found nd no failures.
Hi Kirk - Thank you for taking the time to let us know about your experience and for the 5-Star Review!
Today, I arrived on site for a gas repair and heating maintenance. Conducted gas repair by extending the black pipe outside of the furnace housing to meet code standards. Inspected the furnace ignitor, which showed a good reading of 33 ohms. Checked the pressure switch and found a small bug in the tubing; tubing was free and clear of debris. Noticed condensation rust under the inducer and water stains against the housing. Observed that screws won't tighten down anymore; recommended using high-temperature silicone if the issue persists to prevent fumes from leaking inside the furnace housing. Pulled and cleaned the flame sensor; noted heavy rust on one flame rollout switch. Identified a leak from the PVC drain of the AC inside the housing and over the switch. Turned the system on in heat mode; encountered error code 4+7 indicating an ignitor circuit fault. Reset the power, and the furnace started successfully. Ended the call for heat and initiated another call; the furnace ope
Garbage Disposal Is Backed Up and There Is a Slow Leak: I arrived at the job site and noticed the garbage disposal was leaking and I told her usually when is leaking the best thing is replacing it. when she confirm the ok I started replacing it it was a little difficult because the drain was higher then the disposal so I had to work around it. once I was done I tested a few times and make sure everything was working properly collected all my tools and clean up my work area. THANK YOU FOR CHOOSING VITO
Install New Ductwork: removed all old and damaged flex duct and installed new collars and installed new flex duct and made sure everything was sealed up and had good air flow
FALL CHECK checked filter 16x20x1, checked indoor blower motor and wheel, checked emergency heat strips all electrical wires safety and connections checked temperature rise return air temperature 72 , supply air temperature 113 , checked heat pump only return air temperature 74 , supply air temperature 132 ,checked condenser motor and coil, checked contactor and capacitor, checked defrost board, controls and operation, checked outdoor air temperature 68 , checked discharge air temperature 63, checked freon level liquid line temperature 93 , suction line temperature 151 GOODMAN MODEL NUMBER GSZ140301KG SERIAL NUMBER 2205437658
09/11/2024 upon arrival of home I performed a full plumbing inspection checked all toilets and drains for stoppages checked all valves and faucets for leaks checked the disposal which is new due to recent remodel checked the 65 gallon electric heater customer is interested in tankless but says that she will look around before making a decision. does not want comfort advisor at the time.
08/29/2024 I arrived at my customer home for a one system Ac maintenance outdoor temperature is 82 degrees at this time customer like his/her thermostat set between 65/80 degrees in the home I adjusted customer thermostat five degrees below the room temperature in AC mode customer provided all air filters I flush the indoor drain pipe and drain pump check all amps and components indoor and outdoor furnace 115v input drawing 7.2 amps, blower fan motor drawing 7.0 amps, compressor drawing 6.4 amps, outdoor fan motor drawing 0.5 amps, outdoor power input drawing 11.6, outdoor coil clean ac system working properly at this time.
08/23/2024 upon arrival of home I performed a full plumbing inspection I checked all drains and toilets I checked all valves and faucets I checked the 50 gallon gas heater I checked the disposal as well customer has a leaking hosebib that I gave options for.
08/21/2024 removed foam tape insulation and strapping rewrapped piping with insultube insulation and strapping wrapped valve handle and body had customer inspect coverage all checks good
08/19/2024 NO AC checked furnace found not off on a water safety, checked Condensing unit found blown capacitor 45/7.5 MFD capacitor, replaced part, checked operation ac is working cooling fine at this time checked temperature split return air temperature 73 , supply air temperature 53 BRYANT MODEL NUMBER 126BNA048-A SERIAL NUMBER 4114E18151
08/14/2024 I arrived at my customer home for the ac system not working I did a system check and find one bad run capacitor I removed and replaced one run capacitor ac system working at this time
08/08/2024 Today, I arrived on site to address the customer's AC leaking issue. After assessing the situation, I performed the following tasks: Flushed the condensate drain with water and vinegar using a galo gun (x5) to ensure proper drainage. Tested the system by turning it on to check for any malfunctions. Verified that the system is cooling properly with a supply temperature of 35. would need ladder to access drain line from outside. Units drain does not go down to unit. Based on my assessment, the system is functioning correctly and the AC leaking issue has been resolved. No further repairs, replacements, or additional services are required at this time.
Two Toilets In Basement and Pump Clogged 08/01/2024 I arrived at the job site. the showed me the bathroom and injector pump that was stuck... I spoke with the lady and told her I was going to disconnect the pump and draining the water out the injector pump. once I disconnected and open the pit is was full of gloves paper towels and baby wipes. the footer was stuck with a glove and that the reason the pump stop working also it didn't have weep hole and it for air, if it doesn't have that whole the pipe would fun but it won't push what it need to. once I was done I clean my work area and collected all my tools I made sure everything was clean and running properly. THANK YOU FOR CHOOSING VITO.
07/16/2024 Today, I arrived on site for AC maintenance and found the following: Furnace: Filter was already replaced by the owner. Blower amps and voltage in the furnace are good. Condensate drain is free and clear. System cooling with a temperature split of 15 (59 supply, 74 return). Flex line for gas going into the furnace housing is touching the furnace housing. Repairs are needed to fix the gas line and bring it outside of the furnace. AC Unit: Pressures look good. Voltage across the contactor is good. Capacitor is within specifications. Voltage and amps within the unit are good. No burn marks on the contactor. AC unit was a little dirty, but washing it did not significantly change the pressures (130/310). Subcool is 15. System is cooling well due to it being a Lennox elite system, but the 15 cooling capacity concerns me. The unit may be a little low on charge, as it is not achieving a 20 split. Overall, the system is cooling at this time, but repairs are needed for
Faulty Thermostat 07/03/2024 arrived. found power switch off next to furnace. thermostat no longer works. need to replace stat. do not turn off switch unless it's an emergency. with permission. replaced stat with t6 pro- Honeywell. system on and running
Local Plumber Call Running Toilet: 07/05/2024 upon arrival of home I noticed that the customer was having issues with basement toilet. customer replaced fill valve and flapper but couldn't get toilet to stop leaking. with the customer consent I replaced the toilet supply line and made sure all other connections were good. restored water to toilet and checked for leaks. found no further failures.
07/01/2024 AC CHECK checked and cleaned condensate pan. line and trap with no safety switch, no water safeties, checked indoor blower motor and wheel, checked filter 20x25x1, checked temperature split return air temperature 73 , checked supply air temperature 53 , checked condenser motor and coil, checked contactor and capacitor, checked all electrical wires and connections found no surge protector, outdoor air temperature 67 discharge air temperature 84, checked freon level liquid line temperature 73 , suction line temperature 47 BRYANT MODEL NUMBER 126BNA048-A SERIAL NUMBER 4114E18151
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
AC Maintenance 06/18/2024 SPRING CHECK checked and replaced filter 14x24x1 , checked indoor blower motor and wheel, checked condensate pan, line, with no safety trap. checked over flow safety switch, checked temperature split return air temperature 73 , supply air temperature 53,checked condenser motor and coil, checked capacitor and contactor, checked all electrical wires and connections, no surge protector, checked outdoor air temperature 85 , checked discharge air temperature 96 checked freon liquid line temperature 83 , suction line temperature 59 , LENNOX MODEL NUMBER XC14-030-230-03 SERIAL NUMBER 5811A02724
Thank you, Linda!