Dependable HVAC & Plumbing Services In Takoma Park MD
At Vito Services in Takoma ParkMD, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Takoma Park’s most capable hands, and let us improve your living standards because you’re entitled to the best.
We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the Takoma ParkMD community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!
Recent Jobs and Reviews in Takoma Park, MD
Our Local Reviews by City
- Adelphi, MD (3)
- Aldie, VA (1)
- Alexandria, VA (6)
- Arlington, VA (4)
- Ashburn, VA (5)
- Aspen Hill, MD (2)
- Berwyn Heights, MD (1)
- Bethesda, MD (37)
- Bowie, MD (3)
- Boyds, MD (1)
- Brambleton, VA (1)
- Brookeville, MD (1)
- Burke, VA (1)
- Cabin John, MD (1)
- Centreville, VA (3)
- Chantilly, VA (4)
- Chevy Chase, MD (10)
- Clarksburg, MD (1)
- College Park, MD (1)
- Damascus, MD (1)
- Derwood, MD (1)
- Fairfax, VA (15)
- Fairfax Station, VA (3)
- Fort Washington, MD (3)
- Frederick, MD (2)
- Gaithersburg, MD (14)
- Germantown, MD (6)
- Great Falls, VA (2)
- Haymarket, VA (11)
- Herndon, VA (9)
- Hyattsville, MD (3)
- Kensington, MD (3)
- Laytonsville, MD (1)
- McLean, VA (5)
- Montgomery Village, MD (1)
- North Bethesda, MD (4)
- North Potomac, MD (1)
- Oakton, VA (3)
- Olney, MD (7)
- Poolesville, MD (1)
- Potomac, MD (17)
- Potomac Falls, VA (1)
- Reston, VA (3)
- Rockville, MD (28)
- Silver Spring, MD (37)
- Springfield, VA (1)
- Sterling, VA (2)
- Takoma Park, MD (2)
- Upper Marlboro, MD (1)
- Vienna, VA (4)
- Washington, DC (93)
Job Locations and Reviews
Main Line Stoppage: arrived onsite, main line blockage between 2nd floor bathroom and 1st floor powder room bathroom. pulled 2nd floor bathroom toilet and set it in bathtub. scraped wax off of flange. set up K-60 snake. snaking cables would not fit through snake machine at first so we had to take apart the drive belt and the jaw set and adjust them so cables would fit through. jaw set was restricting the 7/8" cables and not allowing cables to fit through machine. also had to take apart clutch and adjust it so that we could properly snake the drain. existing flange was open spigot style flange with 45 degree angle facing towards us so it was difficult to remove the cables because of the bend. snaked approximately 45' with K-60 and hit blockage around 30 feet. ran lavi faucet while removing cables from drain to aid in flushing out the line. ran water from nearby toilet supply line into drain for 10 minutes to ensure the blockage was clear. set new wax ring and closet bolts on flange. set
Slow Draining Toilets: arrived onsite, customer has 1st and 2nd floor bathroom blockage issues. 2nd floor full bathroom all 3 fixtures are backed up. 1st floor half bathroom lavatory sink is draining fine but toilet seems to be clogged (potentially just an old toilet needing to be replaced and that is the reason for the slow drainage). basement bathroom all 3 fixtures are draining normally. located cleanout in basement floor, opened it up and ran garden hose down - drained normally. was able to plunge 1st floor toilet to get water to go down. attempted to clear 2nd floor toilet with plunger and auger to no avail so at that point I knew it was a main line blockage. will come back tomorrow to pull 2nd floor toilet and snake with K-60.
1st Floor Tub and Toilet Slow: arrived onsite, customer has 1st and 2nd floor bathroom blockage issues. 2nd floor full bathroom all 3 fixtures are backed up. 1st floor half bathroom lavatory sink is draining fine but toilet seems to be clogged (potentially just an old toilet needing to be replaced and that is the reason for the slow drainage). basement bathroom all 3 fixtures are draining normally. located cleanout in basement floor, opened it up and ran garden hose down - drained normally. was able to plunge 1st floor toilet to get water to go down. attempted to clear 2nd floor toilet with plunger and auger to no avail so at that point I knew it was a main line blockage. will come back tomorrow to pull 2nd floor toilet and snake with K-60.
Friendly, professional, thorough
Hi Kate - "Friendly", "Professional" and "Thorough" are all words we love to hear in our technician reviews. Thank you for letting us know about your experience with Vito Services and for the 5-Star Review!
FALL HVAC CHECK checked and replaced customer supplied filter 14x20x1 , checked indoor blower motor and wheel, found no ecm motor surge protector, checked and cleaned burners and heat exchanger, cleaned flame sensor, checked inducer draft motor and flue, checked all safeties and limits, checked all condensate line and tubes, checked condensate pump, found no humidifier or uv light system, checked temperature rise 40-70 HI 30-60 Lo return air temperature 64 supply air temperature 109,. CARRIER MODEL NUMBER 59TP6C100V21-20 SERIAL NUMBER 0624A44536
HVAC Parts Install: I returned today to replace old thermostat with new thermostat due to it failing. I replaced it with a T4 thermostat wired it all back together and tested the thermostat and the unit. Ran it through its cycles and kicked on. I left the unit running and heating. Keep in mind the unit has reached its life expectancy and something else can possibly go wrong. If there's any issues or concerns please feel free to give us a call. Final temperature rise. Return air temperature 69 and supply air temperature was 124. All okay for now I let the unit run for about 45 ! minutes before I left. And I did show the client how to use the new T stat. I will collect the remaining balance of $334.13 Recommendations: I recommend clients start looking into upgrading full system.
NO HEAT #5 checked boiler found no power going to boiler, found power switch turned off, turned power back on checked operation found water around boiler #5 have bad pressure relief valve and extrol expansion tank watts ET-15
Unit 5 Has No Heat: NO HEAT APT #5 Arrived to the customer building found basement door locked, no one here with the key, will have to reschedule call
Boiler Parts Install: replaced gas valve, pilot assembly, pilot tube, checked operation boiler is working heating fine at this time, customer needs to turn thermostat to there comfort setting ENERJET MODEL NUMBER BG-3 SERIAL NUMBER 34763
Boiler At Bottom of Building Not Heating: NO HEAT BOILER entered boiler room with 6 boilers asked which one has the problem he said #4 boiler, checked boiler found that it's been butchered all some of the safeties been jumped out, the pilot assembly and pilot tube is missing, most likely the gas valve is bad, cannot get the boiler operating with missing parts ENERJET MODEL NUMBER BG-3 SERIAL NUMBER 84768
I arrived at my customer home for a boiler system flush I drained the boiler flush the system with chemical and water Rinse with vinegar refill the boiler bleed all radiators and start up boiler system working properly at this time.
I arrived at my customer home for a one system heat maintenance outdoor temperature 43 at this time customer like his/her thermostat set between 65 and 80 in the home I adjust customer thermostat 5 above the room temperature in heat mode boiler systems working pipes are clogged no water cycling through the pipes I recommend a full boiler system flushing need to return on Monday to complete work and pick up full payment
checked out boiler for proper operation. customer does have 4 mini splits as well running with boiler. tech did recommend strap for expansion tank and also new backflow prevention and quickfill
I serviced carrier gas furnace. 16x20x4 filter is dirty and customer. ignitor is 48 ohms. flame sensor is dirty I cleaned and reinstalled. I also change humidifier canister and gasket as well as tested operations and set to number 5 setting. inducer motor pulling .70, blower 3.4. return is 70 supply 135. I checked all rollout and safety switches. I completed xo combustion analysis stack temp 327, oxygen 9.2, co 39 ppm. Gas furnace is heating properly at this time. Thank you for choosing vito services.
Examined area of concern by customer. Performing Preventative Maintenance Plumbing Check today. Water heater 20yrs old. Flushed directly into sump pump well I'm same room. Sump Pump is fully operational. Inspected additional pump in home and it also is fully operational. Customer states home is in good plumbing condition and she would just like water heater serviced. Laundry room has no malfunctions. Performed Water Quality test in laundry room. Chlorine levels are low with a reading of 0.6ppm. Hardness levels are Moderately Hard with a reading of 7GPG. Formulated options for customer approval. Customer has accepted options for future references.
HVAC Parts Install: arrived. replaced inducer motor. inducer motor my last visit no power threw the inducer motor. owner informed me of a recent power surge in home. inducer could have been damaged during power surge. controle board is good at this time and thermostat is good at this time.replaced inducer and tested system system on and heating properly at this time.
I serviced duel fuel carrier system. 16x25x1 filter is clean homeowner replaced beginning of month. inducer is pulling .41 amps. blower pulling 5.2 amps and capacitor is reading 14.50 out of 15. I flushed 90 percent drain trap as well as test condensate pump. Dampers are in open positions. I checked all safeties, rollouts and high temp switch. I checked 24 volt connections at transformer and at board and tightened connections. I tested outdoor unit in defrost controls. fan .69 amps compressor amps 6.2. 45/5 cap reading 43 and 4.8. surge protector still operational on outdoor unit
Today, I arrived on site for a no heat issue. Customer reported no heat from the system. Observed that the thermostat was black upon arrival. Noticed that power was off to the system initially. Turned the power on, and the thermostat turned off as expected. The system attempted to start but displayed error code 45. Error code indicated that the inducer failed to start. Checked voltage to the inducer motor; confirmed 120v is present. Inducer motor did not start despite the voltage being adequate. Recommended replacing the inducer motor to resolve the heating issue.
Furnace Issues: I arrived at my customer home for a boiler system not working I did a full system check and find one bad boiler pump i recommend a replacement of the boiler pump system turned off at this time
I arrived to my customer for an HVAC Fall Maintenance. I inspected filter and is clean at this time. I checked ignitor ohms 46 ohk. I also cleaned dirty flame sensor. I took temp rise on return and supply. I took amp reading on all major components and motors as well as check safeties operation. I completed combustion analysis on 80 percent furnace. system is heating properly at this time. Thank you for choosing vito services.
AC Maintenance 08/20/2024 SUMMER CHECK checked and replaced filter 20x25x1, checked indoor blower motor and wheel, checked condensate pan, line, pump with no trap or water safeties, added condensate tablets, checked temperature split return air temperature 72 , supply air temperature 58 , checked condenser motor and coil, checked contactor and capacitor, checked all electrical wires and connections, found no surge protector, checked outdoor air temperature 68 , checked discharge air temperature 76 , checked freon level liquid line temperature 72 suction line temperature 68 , RHEEM MODEL NUMBER RA14AZ30AJ1NA SERIAL NUMBER W402332774
08/13/2024 I arrived at my customer home for a one system Ac maintenance outdoor temperature is 84 degrees at this time customer like his/her thermostat set between 65 and 80 degrees in the home customer provided all air filters I adjusted customer thermostat five degrees below the room temperature in AC mode I flush the indoor drain pipe check all amps and components indoor and outdoor ac system working properly at this time.
08/09/2024 Arrived on site and met the property engineer. he told us that in jewelry store they had a extremely high water bill and the meter kept spinning. we investigated the store and the water meter and found that the toilet water level was higher then the flush valve and caused the toilet to keep constantly filling all throughout the day. we adjusted the level and checked to make sure it didn't fill to much anymore. we informed the store owners and the engineer of what happened and cleaned out the work area. Thank you for choosing Vito
08/01/2024 arrived on site for a plumbing inspection started by flushing heater customer showed me where heaters are at and customer has a parallel set up having 2 50 gallon electric heaters notice heater on the right is from 2015 with heavy rush in the heater also notice no power going into heater and hot water pipe feeding into the other heater was cold meaning only one heater is working. went back up stairs and brought to customer attention she is currently getting one bathroom remodel inspected kitchen and other bathroom and found no issues told customer about my findings on the heater and gave her investment options for a 50 gallon short electric heater customer said they will need time to think about thank you for choosing Vito.
08/01/2024 Looked at assembly which was displaying a drip about every 15 seconds consistently. Jose noticed the puddle about a week after I certified the assembly. He also mentioned that there had been a water shut down here for some internal work. I quoted Mr. Canales $325. to take assembly apart and clean. Since assembly is so new ( just over a year) I thought that may be all that was needed. Mr. Canales did not like that price too much. I went over all the options with him and then decided I would " try something stupid". I did a quick flush on test cocks 2 ,3 and 4. That stopped the drip. Mr. canales said he would mail the $90. check
08/01/2024 I arrived at my customer home for a one system AC maintenance outdoor temperature is 83 at this time customer like his/her thermostat set between 65 and 80 in the home I had just customer thermostat 5 below the room temperature in AC mode customer provide all Air filter I flushed indoor drain pipe and drain pump check all apps and components indoor and outdoor AC system working at the time.
Mr Aaron was most helpful, explained things, took his time.
Thank you for your kind words, Dr. Argani. We're glad to hear that you had a positive experience with our tech Aaron. We appreciate your feedback and will continue to strive to provide excellent service to all of our customers.