At Vito Services in Takoma ParkMD, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Takoma Park’s most capable hands, and let us improve your living standards because you’re entitled to the best.

We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the Takoma ParkMD community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!

Recent Jobs and Reviews in Takoma Park, MD

Rated 5.0 out of 5 stars based on 1 customer reviews

Job Locations and Reviews

Andrew  B.
Andrew B. Checked in
I arrived at my customer home for a one system heat maintenance outdoor temperature 43 at this time customer like his/her thermostat set between 65 and 80 in the home I adjust customer thermostat 5 above the room temperature in heat mode boiler systems working pipes are clogged no water cycling through the pipes I recommend a full boiler system flushing need to return on Monday to complete work and pick up full payment
Takoma Park, MD 20912
Cordell B.
Cordell B. Checked in
checked out boiler for proper operation. customer does have 4 mini splits as well running with boiler. tech did recommend strap for expansion tank and also new backflow prevention and quickfill
Takoma Park, MD 20912
Brandon  B.
Brandon B. Checked in
I serviced carrier gas furnace. 16x20x4 filter is dirty and customer. ignitor is 48 ohms. flame sensor is dirty I cleaned and reinstalled. I also change humidifier canister and gasket as well as tested operations and set to number 5 setting. inducer motor pulling .70, blower 3.4. return is 70 supply 135. I checked all rollout and safety switches. I completed xo combustion analysis stack temp 327, oxygen 9.2, co 39 ppm. Gas furnace is heating properly at this time. Thank you for choosing vito services.
Takoma Park, MD 20912
Bobby I.
Bobby I. Checked in
Examined area of concern by customer. Performing Preventative Maintenance Plumbing Check today. Water heater 20yrs old. Flushed directly into sump pump well I'm same room. Sump Pump is fully operational. Inspected additional pump in home and it also is fully operational. Customer states home is in good plumbing condition and she would just like water heater serviced. Laundry room has no malfunctions. Performed Water Quality test in laundry room. Chlorine levels are low with a reading of 0.6ppm. Hardness levels are Moderately Hard with a reading of 7GPG. Formulated options for customer approval. Customer has accepted options for future references.
Takoma Park, MD 20912
Aaron W.
Aaron W. Checked in
HVAC Parts Install: arrived. replaced inducer motor. inducer motor my last visit no power threw the inducer motor. owner informed me of a recent power surge in home. inducer could have been damaged during power surge. controle board is good at this time and thermostat is good at this time.replaced inducer and tested system system on and heating properly at this time.
Takoma Park, MD 20912
Brandon  B.
Brandon B. Checked in
I serviced duel fuel carrier system. 16x25x1 filter is clean homeowner replaced beginning of month. inducer is pulling .41 amps. blower pulling 5.2 amps and capacitor is reading 14.50 out of 15. I flushed 90 percent drain trap as well as test condensate pump. Dampers are in open positions. I checked all safeties, rollouts and high temp switch. I checked 24 volt connections at transformer and at board and tightened connections. I tested outdoor unit in defrost controls. fan .69 amps compressor amps 6.2. 45/5 cap reading 43 and 4.8. surge protector still operational on outdoor unit
Takoma Park, MD 20912
Aaron W.
Aaron W. Checked in
Today, I arrived on site for a no heat issue. Customer reported no heat from the system. Observed that the thermostat was black upon arrival. Noticed that power was off to the system initially. Turned the power on, and the thermostat turned off as expected. The system attempted to start but displayed error code 45. Error code indicated that the inducer failed to start. Checked voltage to the inducer motor; confirmed 120v is present. Inducer motor did not start despite the voltage being adequate. Recommended replacing the inducer motor to resolve the heating issue.
Takoma Park, MD 20912
Andrew  B.
Andrew B. Checked in
Furnace Issues: I arrived at my customer home for a boiler system not working I did a full system check and find one bad boiler pump i recommend a replacement of the boiler pump system turned off at this time
Takoma Park, MD 20912
Leon T.
Leon T. Checked in
I arrived to my customer for an HVAC Fall Maintenance. I inspected filter and is clean at this time. I checked ignitor ohms 46 ohk. I also cleaned dirty flame sensor. I took temp rise on return and supply. I took amp reading on all major components and motors as well as check safeties operation. I completed combustion analysis on 80 percent furnace. system is heating properly at this time. Thank you for choosing vito services.
Takoma Park, MD 20912
Danny  W.
Danny W. Checked in
AC Maintenance 08/20/2024 SUMMER CHECK checked and replaced filter 20x25x1, checked indoor blower motor and wheel, checked condensate pan, line, pump with no trap or water safeties, added condensate tablets, checked temperature split return air temperature 72 , supply air temperature 58 , checked condenser motor and coil, checked contactor and capacitor, checked all electrical wires and connections, found no surge protector, checked outdoor air temperature 68 , checked discharge air temperature 76 , checked freon level liquid line temperature 72 suction line temperature 68 , RHEEM MODEL NUMBER RA14AZ30AJ1NA SERIAL NUMBER W402332774
Takoma Park, MD 20912
Andrew  B.
Andrew B. Checked in
08/13/2024 I arrived at my customer home for a one system Ac maintenance outdoor temperature is 84 degrees at this time customer like his/her thermostat set between 65 and 80 degrees in the home customer provided all air filters I adjusted customer thermostat five degrees below the room temperature in AC mode I flush the indoor drain pipe check all amps and components indoor and outdoor ac system working properly at this time.
Takoma Park, MD 20912
Anthony V.
Anthony V. Checked in
08/09/2024 Arrived on site and met the property engineer. he told us that in jewelry store they had a extremely high water bill and the meter kept spinning. we investigated the store and the water meter and found that the toilet water level was higher then the flush valve and caused the toilet to keep constantly filling all throughout the day. we adjusted the level and checked to make sure it didn't fill to much anymore. we informed the store owners and the engineer of what happened and cleaned out the work area. Thank you for choosing Vito
Takoma Park, MD 20912
Carlos  D.
Carlos D. Checked in
08/01/2024 arrived on site for a plumbing inspection started by flushing heater customer showed me where heaters are at and customer has a parallel set up having 2 50 gallon electric heaters notice heater on the right is from 2015 with heavy rush in the heater also notice no power going into heater and hot water pipe feeding into the other heater was cold meaning only one heater is working. went back up stairs and brought to customer attention she is currently getting one bathroom remodel inspected kitchen and other bathroom and found no issues told customer about my findings on the heater and gave her investment options for a 50 gallon short electric heater customer said they will need time to think about thank you for choosing Vito.
Takoma Park, MD 20912
Paul K.
Paul K. Checked in
08/01/2024 Looked at assembly which was displaying a drip about every 15 seconds consistently. Jose noticed the puddle about a week after I certified the assembly. He also mentioned that there had been a water shut down here for some internal work. I quoted Mr. Canales $325. to take assembly apart and clean. Since assembly is so new ( just over a year) I thought that may be all that was needed. Mr. Canales did not like that price too much. I went over all the options with him and then decided I would " try something stupid". I did a quick flush on test cocks 2 ,3 and 4. That stopped the drip. Mr. canales said he would mail the $90. check
Takoma Park, MD 20912
Andrew  B.
Andrew B. Checked in
08/01/2024 I arrived at my customer home for a one system AC maintenance outdoor temperature is 83 at this time customer like his/her thermostat set between 65 and 80 in the home I had just customer thermostat 5 below the room temperature in AC mode customer provide all Air filter I flushed indoor drain pipe and drain pump check all apps and components indoor and outdoor AC system working at the time.
Takoma Park, MD 20912
Andrew  B.
Andrew B. Checked in
Air Conditioner Not Working 07/16/2024 I arrived at my customer home for AC not working indoor system blowing air just not cold I did a full system check on the outdoor unit and find one bad dual capacitor I removed and replaced one dual capacitor check all amps components systems working at this time.
Takoma Park, MD 20912
Paul K.
Paul K. Checked in
Backflow Preventer Testing 07/15/2024 tested three backflows and they all passed. 7908: pass 7902: pass 7806: pass
Takoma Park, MD 20912
Review
Mr Aaron was most helpful, explained things, took his time.
Dr Sholey Argani - Takoma Park, MD 20912
Response from Vito Services:

Thank you for your kind words, Dr. Argani. We're glad to hear that you had a positive experience with our tech Aaron. We appreciate your feedback and will continue to strive to provide excellent service to all of our customers.

Aaron W.
Aaron W. Checked in
07/10/2024 Today, I arrived on site to address the customer's complaint of improper cooling. Here's what I observed and the actions I took: Improper Cooling in Basement: Noticed sweating ducts in the un-insulated finished basement, which has been an ongoing issue. No damper to control airflow through the basement plenum. Recommended installing a damper to minimize airflow through the basement plenum and improve cooling. Replaced the 1-inch filter with a 4-inch pleated filter for better filtration. Improving Airflow: Closed all basement supplies to improve airflow upstairs. Checked all supplies and returns upstairs, ensuring they are open. found a return in one bed room blocked not allowing proper circulation in one room. other rooms supply is under a bed. bathroom upstairs has minimal air flow. bed room air flow is improved with closing supplies downstairs. will need to re open supplies in winter for heat. Cooling for Addition: Noticed that the addition is open concept
Takoma Park, MD 20912
Dennell H.
Dennell H. Checked in
07/05/2024 installed new faucet stems and checked for leaks. found no further failures.
Takoma Park, MD 20912
Aaron W.
Aaron W. Checked in
Today, I arrived on site to find that the customer's AC system was not working. However, upon inspection, I found that the system was actually operating when I arrived. Here is a summary of my findings: Compressor voltage and amps are within specifications. The capacitor is in good condition. The temperature split is 20 degrees, with a 49-degree supply. The condensate pump and thermostat are both functioning properly. Based on these observations, I believe that the issue that may have caused the system to be off could be related to the condensate pump or thermostat. However, both of these components are currently working fine. At this time, the system is on and cooling. No repairs, replacements, or additional services are recommended based on the current condition of the system.
Takoma Park, MD 20912
Dennell H.
Dennell H. Checked in
Plumbingt Call Leaky Shower and Faucet 07/02/2024 upon arrival of home I noticed that the three handle shower in the hall bathroom was leaking constantly. it was coming from hot side. I explained to customer that I could replace the hot side stem for $301. I then explained and recommended to replace both for $451. the customer agreed. I am retrieving parts from vendor and will return when parts are in.
Takoma Park, MD 20912
Leon T.
Leon T. Checked in
AC Maintenance: 06/12/2024 Goodman I checked the filter was clear .I check indoor blower I check the indoor wheel compartment for any construction found none. I checked the blower capacitor it doesn't have any problem and still good. I checked the EVAP coil it looks clean. I checked the condensing line the water is flowing fine in the pipe. I just checked all wirings and connections found okay. I checked my delta TI got to return air temperature of 70" in supply air temperature of 50. and then I went to the outdoor condenser unit was okay.
Takoma Park, MD 20912
Andrew  B.
Andrew B. Checked in
I arrived at my customer home on 06/10/24 for the ac not working I did a full system check and find the contactor burn Pitt outdoor and a broken wire indoor I repair all wires removed and replaced one contactor check all amps and components indoor and outdoor ac system working properly at this time.
Takoma Park, MD 20912
Andrew  B.
Andrew B. Checked in
NO AC Error Code 99 06/07/2024 Reservice from yesterday I did a system check and find the filter too thick I removed and replaced one air filter check all amps and components indoor and outdoor ac system working properly at this time.
Takoma Park, MD 20912
Leon T.
Leon T. Checked in
HVAC Call AC Making Loud Noises 06/07/2024 Goodman Unit the outside unit it's make noise. But is the compressor. but the compressor is working properly. He requested for a supervisor to came here. Cause he want to replace or talk about for different brands.
Takoma Park, MD 20912
Trusted Quality & Service
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 301-315-6100 .

By pressing Submit I agree to receive phone, email, or text messages from Vito Services to the provided mobile number and also agree to the Vito Services terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next