At Vito Services in ViennaVA, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Vienna’s most capable hands, and let us improve your living standards because you’re entitled to the best.

We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the ViennaVA community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!

Recent Jobs and Reviews in Vienna, VA

Rated 5.0 out of 5 stars based on 2 customer reviews

Job Locations and Reviews

George  V.
George V. Checked in
Basement Utility Sink Is Clogged: arrived at location to snake downstairs laundry room sink, snake the sink about 36-40ft before unclogging it, tested with water and no back up or leak occured. customer also wanted me to test laundry standpipe to see if it's covered up or connected to the sanitary system. it's is connected and works fine.
Vienna, VA 22180
Anthony V.
Anthony V. Checked in
No Water In Kitchen Sink: I found out the issue but they said the price is to high.
Vienna, VA 22182
Carlos  D.
Carlos D. Checked in
New Faucet Installation: arrived on site to do work from last week inspection started by shutting water off to the house and drained once drained gather all work related materials and started to work on the 1" prv taped and dope maker adapters and placed on Union and prv then tighten union with gasket then ciut with section of the water main and installed prv and dry fitted once dry fitted pressed in place then worked on removing old saddle vlave. removed saddle vlave and started dry fitting new section in used a 3/4x3/4x1/2 tee and used a slip coupling and used a threaded 1/4 angle stop and set in place then pressed in place and tied in humidifier then started working on laundry tub faucet removed supply lines over off unsecured old faucet once done removed and cleaned up area then set new faucet in place and secured in place then tied supply lines back once tied turned water on and tested for leaks as of ticket completion no leaks were found and house pressure is now at 60 psi cleane
Vienna, VA 22181
Carlos  D.
Carlos D. Checked in
arrived on site for a plumbing inspection started by flushing heater while flushing inspected all plumbing in the house tested house pressure and house pressure is at 90psi which is high customer brought to my attention on a laundry tub faucet he would like replaced and a saddle valves he would like replaced as well. found no other issues in the house as of today inspection bright to customer my findings and gave investment options and customer will like to get everything done but on Monday at 11am since it's kind fo late today and they are busy the rest of this week we will come back with everything needed and need to order new laundry tub faucet wrapped hose up thank you for choosing Vito. note: customer will like us back on Monday at 11 to do work
Vienna, VA 22181
Paul K.
Paul K. Checked in
Commercial Back Flow Preventer Testing: tested six backflow preventers and they all passed but one. I will work on a quote to rebuild and at the same time I've got a call in a Virginia inspector to see to what extent we have to remove the equipment that had been served by the assembly.
Vienna, VA 22182
Ramon P.
Ramon P. Checked in
4" CI Pipe Needs to Be Replaced: replaced 4" cast pipe 14" is was difficult to get in but was able to install
Vienna, VA 22182
Danny V.
Danny V. Checked in
FALL MAINTENANCE ON ONE 80% GAS FURNACE. I checked the air filter and found clogged, the client did not have any for me to replace today. More filters will need to be purchased and replaced by client. I checked the indoor blower wheel motor and noticed oil on the motor, which is a sign of failure. I also noticed a fungle outbreak cultivaing within the unit and circulating back into the air. I checked blower amps found pulling more than normal. I checked inducer draft motor amps found okay. i checked flue vent pipe and performed a combustion analyze test on the system and got a reading of 30ppm , the ppm cannot exceed over 100ppm. I checked and cleaned burners and heat exchanger. I checked all wirings and connections found okay all limits and safetys working okay. I checked the temperature rise i got a return air temperature of 77 and a supply air temperature of 130. I checked the humidifier and found working for now. I did check the humidifier panal and found okay for now. I recommend
Vienna, VA 22181
Review
Paul was very professional. I trusted his knowledgeable skill.
Trung - Vienna, VA 22182
Response from Vito Services:

Thanks, Trung! Paul IS a True Professional and we all trust him here!

Paul K.
Paul K. Checked in
Backflow Preventer Testing: I tested one backflow and it passed.
Vienna, VA 22182
Leon T.
Leon T. Checked in
Thermostat Problems: Upon arrival customer concerns tstat is giving error code on 2020 Furnace /AC. Looked at error code on the tstat, Tstat is rebooting while in heat mode. Cycled system fully checked temp rise is 75-118 with in specs. Checked other components and found nothing abnormal. Customer did state he changed filter. let system run for 20+ min. found no issues at this time. Final cycled system at this time system is fully ops.
Vienna, VA 22182
Leon T.
Leon T. Checked in
Thermostat Problems: Upon arrival customer concerns tstat is giving error code on 2020 Furnace /AC. Looked at error code on the tstat, Tstat is rebooting while in heat mode. Cycled system fully checked temp rise is 75-118 with in specs. Checked other components and found nothing abnormal. Customer did state he changed filter. let system run for 20+ min. found no issues at this time. Final cycled system at this time system is fully ops.
Vienna, VA 22182
Leon T.
Leon T. Checked in
Thermostat Problems: Upon arrival customer concerns tstat is giving error code on 2020 Furnace /AC. Looked at error code on the tstat, Tstat is rebooting while in heat mode. Cycled system fully checked temp rise is 75-118 with in specs. Checked other components and found nothing abnormal. Customer did state he changed filter. let system run for 20+ min. found no issues at this time. Final cycled system at this time system is fully ops.
Vienna, VA 22182
Review
Good Tech! Very professional!
Trung Lam - Vienna, VA 22182
Response from Vito Services:

Thank you, Trung!

Ramon P.
Ramon P. Checked in
Arrived to location. Replace the 4th and 5th floor urinal rubber seal with new seals. Proceed to go to the 4th floor to snake a clogged sink in the Ladies Restroom. Snakes down 45ft to clear. Cleaned up our area.
Vienna, VA 22182
Danny  W.
Danny W. Checked in
FALL HVAC MAINTENANCE CHECK check filter 20x20x4 , checked indoor blower motor and wheel, found no ECM MOTOR SURGE PROTECTOR, checked emergency heat strips all electrical wires safeties limits and connections, checked emergency heat return air temperature 73 , supply air temperature 97 , checked heat pump side return air temperature 75 , checked supply air temperature 105 , checked condenser motor and coil, checked inverter board wiring, connections, no capacitor or contactor, found no surge protector , checked outdoor air temperature 69 checked discharge air temperature 59 , checked freon level liquid line temperature 98 suction line temperature 135 ,. CARRIER MODEL AIR HANDLER NUMBER FE4ANF005 SERIAL NUMBER 2221F22576 CARRIER MODEL HEAT PUMP NUMBER 25VNA836A310 SERIAL NUMBER 3221E12274
Vienna, VA 22181
George  V.
George V. Checked in
Commercial Plumbing, Leak Behind Wall: I arrived at location for 1st floor men bathroom had a crack pipe, looks like someone try to snake it and the snake broke the 2" 45, which wasn't able to repair that only but we have to repair the urinal line in order to make the repair, the PVC was connected to a 6x3 tee cI, we replaced and repiped including the vent to that line as well, we checked for any leaks no leaks occured
Vienna, VA 22182
Danny V.
Danny V. Checked in
FALL MAINTENANCE ON TWO UNITS. #1 MAIN HOME CARRIER 90% HIGH EFFICIENCY GAS FURNACE I checked the aprilair filter and replaced with one costumer provided. I checked the indoor blower wheel motor housing compartment for any obstructions and found none. I checked the blower amps and found within specs. I checked the inducer draft motor and flu vent pipe and found okay I checked inducer amps and found within specs. I checked the heat exchanger and cleaned burners. I checked the flame sensor and cleaned it off today. I checked ignitor ohms and read 57.9ohms I checked the pressure switch found working okay. I checked flames and look consistent. I checked all other limits and safetys all wiring and connections found okay. I got a return air temperature of 78 and a supply air temperature of 121. I flushed drain line connected to collectors box and found no clogs. This unit is only 4yrs old. She is running and heating efficiently as of now. #2 ADD ON SPACE CARRIER 90% HIGH EFFICIENC
Vienna, VA 22180
Danny V.
Danny V. Checked in
FALL MAINTENANCE ON ONE UNIT. The Costumer wanted me to check his heat. I called for heat at thermostat and the unit ran. I checked the filter and found okay for now. The client will have to purchase more and replace soon. I checked the indoor blower wheel motor housing compartment for any obstructions and found none. I checked blower amps and found within specs. I checked the 10mfd capacitor on the blower motor and found within range. I checked the inducer draft motor and flue vent pipe and found okay. inducer amps are within specs. I checked and cleaned heat exchanger and burners. I checked ignitor ouhms and found within specs. I checked flame sensor and cleaned it off today. I checked gas valve 24v okay. I checked pressure switch found okay. I checked all other limits and safetys all wiring and connections found within specs. Recommended temperature rise 40-70. I got a return air temperature of 78 and a supply air temperature of 140. The humidifier that the client has is antiquated
Vienna, VA 22180
Craig M.
Craig M. Checked in
09/18/2024 performed maintenance on Lenox gas furnace landlord & tenet system is good physical and operational conditions all safeties and controls tested within spec thank you for your business
Vienna, VA 22182
Jim V.
Jim V. Checked in
performed maintenance on 2 carrier unit basement system is good physical and operational conditions all safeties and controls tested within specs refrigerant levels tested within spec no loose or damaged wiring attic unit notice error code for system freezing notice evap coil was freezing up inspect unit notice system is low on 410a refrigerant talked with regarding fixing or replacing system sent over quote for replacement thank you for your business
Vienna, VA 22182
Danny V.
Danny V. Checked in
09/05/2024 AC MAINTENANCE ON TWO UNITS. (BOTH UNITS LESS THAN A YEAR) #1 Attic Space I checked filter and replaced with one costumer provided. I checked the indoor blower wheel motor housing compartment and found okay. I also checked blower amps and found within manufacturer recommended. I checked the evaporator coil and found okay I checked the ez trap switch on Condensate drain line and found working I flushed drain line with two gallons of water and found draining properly as of now. I checked every other limits and safety and all wiring and connections found okay. I got a return air temperature of 72 and a supply air temperature of 51. I checked the UV light and found working properly. I checked outdoor coil and found dirty and in need of a chemical cleaning. I checked the outdoor temperature of 76 and a discharge temperature of 89 I checked all components outside working within specs. Suction line temperature 54 liquid line temperature 69 This unit is running and cooling a
Vienna, VA 22182
Leon T.
Leon T. Checked in
09/03/2024 performed ac repair found unit low on 410a and capacitor failed added 4lbs of 410 and replaced Cap supply 53 return 72 compressor 6.0 amp fan .07 subcool 13 super heat 10 system is operational thank you for your business
Vienna, VA 22180
Danny V.
Danny V. Checked in
08/28/2024 AC MAINTENANCE ON TWO UNITS #1 Attic lvl I checked filter and found okay client replaced upon today's arrival. I checked indoor blower wheel motor housing compartment for any obstructions and found okay. I checked indoor evaporator coil and noticed a FUNGLE outbreak cultivating within the unit. I flushed condensate line that holds Safe T switch with a gallon of water and found okay. I checked all limits and safetys all wiring and connections found okay. I got a return air temperature of 80 and a supply air temperature of 60 I checked outdoor condenser coil and hosed down with water for client. I checked out door temperature and got 89 discharge temperature is 99 I checked 45/5 capacitor and found within working range. I checked single pole contactor and found okay. This unit is running and cooling as of now. Recommendations: I would recommend adding an air scrubber to the unit due to the cultivation of fungle spours contaminating the unit and circulating back into the
Vienna, VA 22180
Carlos  D.
Carlos D. Checked in
Plumbing Maintenance 08/28/2024 arrived on site for a plumbing inspection started by flushing heater while flushing inspected all plumbing in the house tested house pressure and is at 60psi which is good water pressure to have and means prv works as of today visit found 2 issues in the kids bathroom flapper seems to be looks old and chain is tight making it hard to flush and in master bathroom fill valves hums while filling brought these to customer attention but said she will talk it over with her husband went back to heater and let flushed for awhile longer then wrapped hose up thank you for choosing Vito.
Vienna, VA 22180
Danny  W.
Danny W. Checked in
AC Maintenance 07/30/2024 SUMMER CHECK ATTIC UNIT #2 checked filter 16x25x1, checked indoor blower motor and wheel, checked condensate pan line and trap, checked 1 water safeties in emergency catch pan , no ez trap safety switch. added condensate tablets, checked temperature split return air temperature 74 supply air temperature 52 , checked supply duct found some of the insulation is starting to come apart the glue on the tape has worn off, checked condenser motor and coil, checked capacitor and contactor, checked all electrical wires and connections, found no surge protector, outdoor air temperature 79 , discharge air temperature 93 , checked freon level liquid line temperature 88 , suction line temperature 65 LENNOX MODEL NUMBER 13ACX-042-230-12 SERIAL NUMBER 1911M16464
Vienna, VA 22182
Anthony V.
Anthony V. Checked in
Commercial Plumbing Call Jetting Roof Stacks 06/24/2024 arrived on site to jet the roof stack lines for maintenance, ran the hose up the side of the building and staged the jet, ran the jet down 7 stacks across the roof, had to stop on the last stack early because a leak was found, 10 ft section of 4" cast iron in the ceiling of the ground floor in room G100, reeled the jet back up and dumped the water, cleaned up work area and left
Vienna, VA 22182
Danny  W.
Danny W. Checked in
AC Maintenance 06/19/2024 SPRING CHECK TOP FLOOR UNIT checked filter 20x20x1, checked indoor blower motor and wheel, checked condensate pan, line, and trap with no safety, added condensate tablets, Checked emergency catch pan float switch, checked temperature split return air temperature 77 , supply air temperature 55 , checked condenser motor, removed vines off condenser coil checked coil, checked capacitor and contactor, checked all electrical wires and connections, checked outdoor air temperature 92 checked discharge air temperature 112 , checked freon level liquid line temperature 96 suction line temperature 62 , LENNOX MODEL NUMBER HS26-042-2P SERIAL NUMBER 5899F 40535
Vienna, VA 22182
Trusted Quality & Service
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 301-315-6100 .

By pressing Submit I agree to receive phone, email, or text messages from Vito Services to the provided mobile number and also agree to the Vito Services terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next