Professional Home Comfort Services for Washington, DC, Virginia & Maryland
It sure is exciting living in the DMV. Sometimes it can even feel like we're at the center of the universe. But that fast-paced style means it's even more important for us to have comfort and security when we're at home. That's the whole reason Vito Services exists - to provide that comfort for our friends and neighbors here in the greater Washington, DC, Virginia and Maryland area.
We've been at it since 1934, and we don't plan on slowing down anytime soon. Give us a chance to help you slow down and enjoy the peace and relaxation your home's supposed to offer - you'll be glad you did.
Our Customers Say It Better Than We Ever Could
One of the greatest joys we experience in our line of work is when we see a new glowing review get posted from one of our customers. We always aim to provide 5-star service, and seeing those 5-star reviews lets us know our hard work is paying off. That's why we're proud to share those reviews with you, so you can get a taste of what it's like to experience the Vito Services difference.
Take a look at what your friends and neighbors have to say, then rest easy in the knowledge that home comfort help is just a phone call away. We're here 24/7 for all your HVAC, plumbing and indoor air quality needs - just call 301-315-6100 and Leave it to Vito!
Recent Jobs and Reviews
Our Local Reviews by City
- Adelphi, MD (3)
- Alexandria, VA (4)
- Arlington, VA (2)
- Ashburn, VA (4)
- Aspen Hill, MD (2)
- Berwyn Heights, MD (1)
- Bethesda, MD (30)
- Bowie, MD (1)
- Boyds, MD (1)
- Burke, VA (1)
- Cabin John, MD (1)
- Centreville, VA (3)
- Chantilly, VA (3)
- Chevy Chase, MD (7)
- Clarksburg, MD (1)
- College Park, MD (1)
- Damascus, MD (1)
- Derwood, MD (1)
- Fairfax, VA (14)
- Fairfax Station, VA (3)
- Fort Washington, MD (2)
- Frederick, MD (2)
- Gaithersburg, MD (11)
- Germantown, MD (5)
- Great Falls, VA (1)
- Haymarket, VA (11)
- Herndon, VA (8)
- Hyattsville, MD (3)
- Kensington, MD (1)
- Laytonsville, MD (1)
- McLean, VA (2)
- Montgomery Village, MD (1)
- North Bethesda, MD (3)
- North Potomac, MD (1)
- Oakton, VA (2)
- Olney, MD (7)
- Poolesville, MD (1)
- Potomac, MD (14)
- Reston, VA (2)
- Rockville, MD (17)
- Silver Spring, MD (30)
- Springfield, VA (1)
- Sterling, VA (1)
- Takoma Park, MD (1)
- Upper Marlboro, MD (1)
- Vienna, VA (2)
- Washington, DC (71)
Job Locations and Reviews
HVAC Checkup: System is a 2017 80% Furnace /AC. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower clean along with evaporator coil. System does have a UV light but not a humidifier. Air filter needs to be changed. Adjusted dampers so customer can get more air flow upstairs. Final cycled system at this time system is operational.
Thermostat Turning Black: I replaced batteries in stat provided by customer and tested. system is working fine at this time thank you for choosing vito services.
NO HEAT CALL This is a tenant owner situation. The tenant advised me that two vents weren't supplying heat. Both of the vents she pointed out were return vents not supply vents. I checked unit and it was running. I put my thermometer at the vent and got a reading of 120. I found the 16254 filter clogged. That also plays a big part in air flow. The filter will need to be replaced. Owner was not available. The office will need to contact landlord to collect payment of $120.00 Thank you for choosing VITO SERVICES.
NO HEAT CALL. Client advise me he had another company come and diagnose the unit. I checked unit and turned it on and called for heating. There was 24v at the board. The fan ran. the inducer ran and the Ignitor came on, the gas valve opened and there was 24v present. The gas valve has been compromised. The ignitor was drawing 90ohms. Recommendations: #1 Replace gas valve $1116.00 #2 Replace gas valve$1026.00 and replaced Ignitor $500.00 Sign up for contract $244.00 #3 Replace unit due to parts being worn and reaching its life expectancy Free estimate. Costumer has decided to go with option #2 We will order gas valve and ignitor and return to do job. We also signed client up for annual maintenance. Thank you for choosing VITO SERVICES.
12/06/2024 I arrived at my customer home for a one system heat maintenance outside temperature is 36 degrees at this time customer like his/her t-stat set between 68 and 80 degrees in the home I adjusted customer thermostat five degrees above the room temperature in heat mode customer provided all air filters I check all amps and components indoor = thermostat, humidity stat, 115v humidifier power, humidifier water line, humidifier drain pipe,115v drain pump working, 3/4 to 1/2" gas pipes, 115v furnace power input, 115v furnace switch, supply temperature 136.8 degrees, return temperature 78.2 degrees, ignitor drawing 1.9 amps, inducer fan motor drawing 1.6 amps, high limited sensor drawing 0.6 amps, pressure switch drawing 0.4 amps, gas valve drawing 0.9 amps, burners clean, heat sensor drawing 0.4 amps, flame sensor clean, flames blue, blower fan motor drawing 3.8 amps, indoor control board,indoor control wiring, furnace 115v to 24v transformer, duct work, vent pipes trane 80% gas fur
I arrived at my customer home for a one system boiler maintenance outdoor temperature 36 at this time customer like his/her thermostat set between 65 and 80 in the home I adjust customer thermostat 5degrees above the room temperature in heat mode I checked all amps and components indoor combustion boiler working properly at this time. customer not at home caretaker open up for me to service the system please call customer for payment
Change Electrical Components Inside Water Heater: customer notified us to come change the electrical part inside of their water heater.Once on site the customer showed me where the heater was located in the bathroom about 10ft in the ceiling. advised customer that I will start to drain down the heater and then go to the supple house to get the proper tools to replace the layer heater element. set up equipment, i hooke up a 50ft water hose to the heater and then turned the supply off so that I can drain down the heater. I then open the pressure life valve to release the pressure inside of the tank. while the heater is drained I headed to the supply store. once back on site the heater was drained down and I used a multi meter to see if their power going to the heater. turned power off. started to dissamlbe the heater by taking the cover off and and then undoing all the wiring for the heater. toom off the thermostat and also took out the old element. installed the new thermostat along wi
Leaking Water Cooler: arrived on site to look at a water cooler that was leaking, took it apart and found that the valve was leaking, found a replacement and quoted the customer for the job $163, customer approved and went through with replacement, took out the old valve and installed a new one, tested for leaks, found no leaks, cleaned up work area and left
Examined area of concern by customer. Customer has viewed water marks on ceiling between foyer and dining area. Requested to view upstairs areas above. 2 standup showers, that sit side to back, show immediate signs of leaking around perimeter. Caulking is discolored and cracked/peeling. Made customer aware of process of repair required and gave customer investment option for me to perform task without warranty. Also, addition to home may be under warranty and customer would like to investigate that aspect. Gave customer mold remediation referral and customer will contact us back if any further assistance is required. Thank you for choosing Vito!
Arrived at location. We were taken to the unit 10 and took the toilet off. We couldn't find a hose bibs near the unit so we put the hose out through the bathroom window and brought it down to the Landry room. Took the toilet off and we about to start the job until they advised us there was a clean out in a storage room. Put the toilet back and went to the Cleanout. Started jetting the line and notice it was clogged. Kept pulling back a lot of grease, Ran the whole jet hose and got it cleared. Cleaned up our area and left.
Arrived on site. Identified pipe to be replaced and made material list. Retrieved new material. Returned on site and opened ceiling. Removed hangers and old pipe. Set new pipe in ceiling and returned hangers. Connected pipe and fittings, reconnecting section. Checked for leaks. Found no leaks.
FALL MAINTENANCE ON ONE UNIT 80% CARRIER GAS FURNACE I checked the 16254 filter and found clogged, the client didn't have any extras at the momentm. I checked the ecm indoor blower wheel motor housing compartment for any obstructions and found a funlge outbreak cultivating within the unit I did notice that the blower motor is exposed to any high voltage power surges by not containing a surge protector on it. I checked blower amps and found within specs. I checked the inducer draft motor and flue vent pipe and found okay. I checked inducer motor and found within specs. I checked the flame sensor and cleaned it off today the flame sensor does have wear on it making it no longer reliable. I checked the igniter reading 55ohms. I checked all limits and safety and all wirings and connections found okay. I checked and cleaned burners and heat exchanger. I checked the temperature rise and I got a return air temperature of 72 and a supply air temperature of 133. I checked humidifier found oka
New Furnace Installation: removed old furnace and set and installed new furnace and tied everything back in and ran equipment and checked for proper operation
HEATING MAINTENANCE: Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower _____ along with evaporator coil. System does not have a UV light or humidifier. _____Air filter ____. Checked condenser unit and found system is amping within specs. Tested starting components (contactor & capacitor) and checked for any loose connections. _Cycled defrost successfully_. Final cycled system at this time system is operational. Maintenance to 2 systems, starting on attic system first.System is a 2022 80% Furnace/AC. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower clean along with evaporator coil. System does not have a UV light or humidifier. Changed air filter in ceiling. Final cycled system at this time system is operational. Checked basement system next system is a 2021 80% Furnace /AC. Checked all compon
I serviced carrier gas furnace. 16x20x4 filter is dirty and customer. ignitor is 48 ohms. flame sensor is dirty I cleaned and reinstalled. I also change humidifier canister and gasket as well as tested operations and set to number 5 setting. inducer motor pulling .70, blower 3.4. return is 70 supply 135. I checked all rollout and safety switches. I completed xo combustion analysis stack temp 327, oxygen 9.2, co 39 ppm. Gas furnace is heating properly at this time. Thank you for choosing vito services.
I arrived at my customer home for a one system heat maintenance outdoor temperature 36 at this time I knocked ring the doorbell call customer cell no answer please call to reschedule customer for another day. I returned, arrived at my customer home for a one system heat maintenance outdoor temperature 36 at this time customer like his/her thermostat set between 65 and 80 in the home I adjust customer thermostat 5 above the room temperature in heat mode I checked all amp and component indoor I recommend a replacement of the fill valve backflow preventer damper gauges expansion tank relief valve and adding an air scoop boiler system 30 years old flames burning blue and orange heat exchanger needed to be clean burners needed to be clean zero PPM in the home 26 PPM combustion test rating systems working at this time.
Examined area of concern by customer. Performing Preventative Maintenance Plumbing Check today. Water heater 20yrs old. Flushed directly into sump pump well I'm same room. Sump Pump is fully operational. Inspected additional pump in home and it also is fully operational. Customer states home is in good plumbing condition and she would just like water heater serviced. Laundry room has no malfunctions. Performed Water Quality test in laundry room. Chlorine levels are low with a reading of 0.6ppm. Hardness levels are Moderately Hard with a reading of 7GPG. Formulated options for customer approval. Customer has accepted options for future references.
Service Heat: I replaced customer 16x20x1 filter. I checked drain safety. return is 73 supply 115. 5 mfd reading 4.4. I recommend replacing ($265). water pump amps is .46 good at this time. blower amps 5.39. I checked voltage at relay and transformer as well as control wiring and tightened down loose connections. tspec water source unit is heating properly at this time. Thank you for choosing vito services.
Toilet Not Working: upon arrival of home I noticed that the powder room toilet was constantly running . replaced fill valve in toilet and checked for leaks. there are no further issues.
arrived on site for plumbing inspection started by flushing heater while flushing inspected all plumbing in the house tested house pressure and house pressure is at 60 psi water heater is from 2006 making it's a 17 year old heater but found no issues on the water heater and as of today inspection found no issues in the plumbing system as of today visit came back downstairs let heater flush for awhile longer then wrapped hose up thank you for choosing Vito. recommendation: 50 gallon gas heater vip:2939 chimney liner: will send a separate email
Leaking Pipe: Arrived at location. We were taken into the basement and saw a stream of water running. They cut the pipe but they told us the leak was originally from the 90. Asked us to cut and abandon the line. The line was connecting to a hose that they were no longer using. Cleaned up our area and left. Will Be back tomorrow to make the repairs.
Basement Toilet and Tub Backed Up: arrived onsite, main line blockage in basement of townhome. searched for cleanout to no avail. pulled basement toilet and snaked approximately 45 feet with K-1500. hit blockage at 40 feet. reset toilet with new wax ring. reconnected supply line and flushed multiple times to check for proper operation and drainage. also ran lavi faucet and bathtub to check for proper drainage. cleaned up and removed all job related debris.
New Furnace: Changed Out Old Furnace in Attic For new one
New Furnace Installation: removed old furnace and set and installed new furnace and tied all flu pipes back in along with gas and wiring and drain lines and installed new thermostat and fired up equipment and checked for proper operation