DMV Service Area

Professional Home Comfort Services for Washington, DC, Virginia & Maryland

It sure is exciting living in the DMV. Sometimes it can even feel like we're at the center of the universe. But that fast-paced style means it's even more important for us to have comfort and security when we're at home. That's the whole reason Vito Services exists - to provide that comfort for our friends and neighbors here in the greater Washington, DC, Virginia and Maryland area.

We've been at it since 1934, and we don't plan on slowing down anytime soon. Give us a chance to help you slow down and enjoy the peace and relaxation your home's supposed to offer - you'll be glad you did.

Our Customers Say It Better Than We Ever Could

One of the greatest joys we experience in our line of work is when we see a new glowing review get posted from one of our customers. We always aim to provide 5-star service, and seeing those 5-star reviews lets us know our hard work is paying off. That's why we're proud to share those reviews with you, so you can get a taste of what it's like to experience the Vito Services difference.

Take a look at what your friends and neighbors have to say, then rest easy in the knowledge that home comfort help is just a phone call away. We're here 24/7 for all your HVAC, plumbing and indoor air quality needs - just call 301-315-6100 and Leave it to Vito!

Recent Jobs and Reviews

Rated 4.8 out of 5 stars based on 251 customer reviews

Job Locations and Reviews

Review
Your technicians are excellent but I always have difficulty with the office staff. Calls aren’t returned, and staff seem to have difficulty pulling up my account and organizing appointments
25yearcustomer - Washington, DC 20015
Carlos  D.
Carlos D. Checked in
arrived on site for a basement faucet that needs repaired customer showed me area to concern and hot side Handel was broken and customer wanted the Handel replace gave customer investment option and she agreed went to supply house to get new Handel once back removed both hot and cold handles then placed new handles in place and secured tested for proper functions and no issues were found thank you for choosing Vito.
Bethesda, MD 20814
Aaron W.
Aaron W. Checked in
Today, I arrived on site for two scheduled maintenance tasks, including one for heating. Heating System Observations: Upstairs system was not operational. A wet switch had turned off the system. Noticed someone was tampering with the AC. Started the system in heat mode. Burner one tube was fluttering badly, even before blower activation. Performed a combustion test on the furnace; CO levels were within range. Detected CO in breathable air: 7 ppm in the attic and 40 ppm in the flue. Recommended replacement of the furnace due to safety concerns. Additional Recommendations: Scheduled a Comfort Advisor visit for next Tuesday to discuss furnace replacement. Noted that the furnace gas pipe obstructs removal; gas will need to be shut off to the house. Basement Furnace Maintenance: Installed a surge protector for the furnace blower motor and ensured it was grounded. Checked the operation of the basement furnace; it is functioning well at this time. The humidifier is operational
Washington, DC 20015
Danny  W.
Danny W. Checked in
SOMETHING IS MAKING NOISE checked the noise complaint customer pointed at the condensate pump on a heat only furnace and humidifier making noise has a bad float switch that will not shut the pump off, pump needs replacing
Washington, DC 20015
Aaron W.
Aaron W. Checked in
Today, I arrived on site for two scheduled maintenance tasks, including one for heating. Heating System Observations: Upstairs system was not operational. A wet switch had turned off the system. Noticed someone was tampering with the AC. Started the system in heat mode. Burner one tube was fluttering badly, even before blower activation. Performed a combustion test on the furnace; CO levels were within range. Detected CO in breathable air: 7 ppm in the attic and 40 ppm in the flue. Recommended replacement of the furnace due to safety concerns. Additional Recommendations: Scheduled a Comfort Advisor visit for next Tuesday to discuss furnace replacement. Noted that the furnace gas pipe obstructs removal; gas will need to be shut off to the house. Basement Furnace Maintenance: Installed a surge protector for the furnace blower motor and ensured it was grounded. Checked the operation of the basement furnace; it is functioning well at this time. The humidifier is operational
Washington, DC 20015
Danny V.
Danny V. Checked in
FALL MAINTENANCE ON ONE UNIT 2008 CARRIED 80% Gas furnace. I checked and replaced 16201 filter and replaced with one Costumer provided. I'm adjusted the gas pressure because the temperature rise was top high. i checked inducer draft motor and found pulling high amps. i checked Ignitor and flame sensor and found worn out and no longer reliable. i checked 10mfd capacitor and found low on capacitance. I performed a combustion analyze test and got a reading over 100ppm making unit unsafe to run. I did advise client. I RECOMMEND THE REPLACEMENT OF 2008 FURNACE. Original furnace is 132,000 BTU will replace with 110,000 BTU Furnace size Height: 33 1/2 inch tall Width: 21 inch Depth : 24 inch Return drop is 14x20 Carrier furnace availability final price $7529.00 Including 10% discount and $300 coupon off. 2 year labor warranty. The costumer has agreed to go ahead and move on with getting the furnace. We will provide 3 space heaters for costumer. Client will pay full amount of
Olney, MD 20832
Brandon  B.
Brandon B. Checked in
I inspected 2006 carrier gas furnace. I cleaned flame sensor and checked micro amps 3.3. I checked high limit and rollout safeties. I checked 24 volt at transformer and at control board and tightened connections. ignitor reading 53 ohms. inducer pulling 1.5 amps blower pulling 6.5 amps. return is 69 supply is 125.3 20x25x4 filter has already been replaced. I also completed co combustion analysis 308 stack temp, oxygen level 7.1, co 64 ppm. I tested system in low and high stages of heat. Furnace is past life expectancy but still heating at this time. Thank you for choosing vito services.
Burke, VA 22015
Brandon  B.
Brandon B. Checked in
Heat Turns On, Then Turns Off: daikin gas furnace turned on when I increased the heat. I cleaned flame sensor and checked micro amps reading 3.1. I decreased gas pressure. inducer reading .38 amps ok. blower 4.2 amps ok. return 70 supply 124. Co combustion stack temp 330, oxygen 7.4, co 50 ppm heat exchanger in good shape. ignitor ohms 56 ok. filter and return grill is dirty needs to be replaced and cleaned. system is heating properly at this time.
Fairfax, VA 22030
Parris B.
Parris B. Checked in
Call to do maintenance on 2 heat pump systems. Checked upper zone system first. System is a 2014 multi stage heat pump. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower clean along with evaporator and steam humidifier in good condition. System does not have a UV light. Air filter needs to be changed. Checked condenser unit and found system is amping within specs. Tested starting components (contactor & capacitor) and checked for any loose connections. Cycled defrost successfully. Final cycled system at this time system is operational. Checked basement zone system next. System is a 2021 multi stage heat pump. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower clean along with evaporator and steam humidifier in good condition. System does not have a UV light as well Air Scrubber is recommended fo
McLean, VA 22102
Review
Aaron Wade was very knowledgeable and a clear and direct communicator, showing me what was wrong with the hardware and explaining why/how it occurred. It was perfect.
Max - Washington, DC 20002
Review
Brandon was Superb
Scott - Fairfax Station, VA 22039
Dennell H.
Dennell H. Checked in
custoemr has 50 gallon gas heater that will stay lit but will not ignite full pilot. I am recommending that customer has gas control valve. I have located gas control at Ferguson's in Beltsville . part no s100262939. customer will need to have valve put in tomorrow . will contact parts about part.
Boyds, MD 20841
Brandon  B.
Brandon B. Checked in
customer us advised that their water heater was leaking from the top and also not heating. upon arrival of contacted Todd to ensure where the heater was located. once inside of the restaurant I was greeted by employees who took me to the back area where the heater was located. I can observe corrosion and also the water heater leaking from the exhaust manifold. also I can see that fernco connected to the exhaust was not securely on the PVC piping. tighten the fernco and seen that the leak was still occurring and was coming from the small blue purge lines. clean up the access water of the top the heater and dried the heater to the best of my ability. once the heater was dry I then turned the power to the heater on. Error code 57-0 came on screen stating either the flame sensor was not grounded our water in the combustion chamber. the flame sensor was ground was but corroded. unbolted the cap on the combustion chamber and observed a heavy flow of water coming from the chamber. once the
Washington, DC 20006
Danny  W.
Danny W. Checked in
Furnace Is Out, NO HEAT MAKING NOISE checked boiler found off at the power switch by Vito technician saying it was coming from the gas valve after 10 minutes of run time . Checked all safeties and limits, circulator pump, motorized vent damper so far boiler is working fine. Didn't make any noise while I was here, just cleaned flame sensor and raised limit switch to 180 BURNHAM MODEL NUMBER 206NIL-TEI2 SERIAL NUMBER 65173040
Washington, DC 20011
Dennell H.
Dennell H. Checked in
upon arrival of home I replaced the powder room toilet with a customer supplied toilet. also replaced anglestop valve in upstairs hall bath to toilet. restored water and checked for leaks. found no further failures. customer would like office to call and collect
Gaithersburg, MD 20882
Carlos  D.
Carlos D. Checked in
Not Hot Water, Price to Replace Water Heater: arrived on site for a customer who has no hot water customer showed me area of concern customer has a 80 gallon electric heater customer they notice there water wasn't heating up and today water was cold took off upper and lower element cover used hot stick and notice I have no power going to the heater went to the breaker panel and found breaker for heater placed hot sick and nothing was reading customer took apart wire nuts and tested again and have no power. customer had a electrician working in the house while on site and had him checked and confirmed that the breaker is bad recommend customer to replace that first and if they still have a issue I'll leave options to repair up to replace the heater also customer wanted to see about a water filtration system as well thank you for choosing Vito. note:48 dispatch can be credit to which options the customer picks recommendations: option 1: full electrical rebuild st:874 vip:743 op
Potomac, MD 20854
Carlos  D.
Carlos D. Checked in
arrived on site to a customer who will like there water heater flushed customer showed me area of concern and said it's been 2 years since he gotten the heater flushed qouted customer to flush heater and customer will get billed. connected hose and ran it outside and turned on drain valve and started flushing while flushing notice water heater is from 1998 making it a real old heater water heaters have a life span of 8-12 years if maintained properly and also notice it doesn't have a cheniny liner when customer came back to see how it was going and informed him the age of the heater and also if he was looking to get to replaced by code we will have to install a chimney liner for it to pass code. customer asked about tankless options as well and explained the difference between the two units and best options for each of customer will like to go the tankless options I recommend getting a inline water conditioner so instead of flushing the tankless every year you can flush them every 3 ye
Potomac, MD 20854
Aaron W.
Aaron W. Checked in
Today, I arrived on site to assess the boiler system. Main controller board was found burnt but still operational. Gas valve also showed signs of burning yet continued to function. Wire harness connected to the gas valve was burnt. Cut and snipped all damaged wires and reattached them. Successfully got the boiler back up and running. Issue was caused by the sight glass being left open, allowing flames to damage the system. Current status: System is operational at this time. Recommended future actions include replacing the control board, gas valve, and gas valve harness. ** the 2 pipes that has signs of a leak that need to be replaced. above the boiler. office to handle quote. Suggested adding a red faceplate cover to the boiler power switch for safety.
Washington, DC 20002
Brandon  B.
Brandon B. Checked in
I inspected 80 percent gas furnace. I replaced 20x25x4 filter and dated. I replaced humidifier pad and set controls to 35%. flame sensor was dirty so I removed and cleaned, sensor is also reading 3 micro amps. I checked all safeties and switches. ignitor is reading 48 ohms. blower is pulling 4.03 amps and inducer pulling 1.04. return is 72 supply is 128. I also completed co combustion analysis on system. gas furnace is heating properly at this time. Thank you for choosing vito services.
Fairfax, VA 22033
Danny  W.
Danny W. Checked in
FALL CHECK checked and replaced customer supplied filter 15x20x1, checked indoor blower motor and wheel , cleaned and checked burners and heat exchanger, cleaned and checked flame sensor, checked all safeties and limits, checked all water lines and tubes, checked temperature rise 45-75 return air temperature 79 , supply air temperature 141 , have humidifier that doesn't work, CARRIER MODEL NUMBER 595C2C060S14 SERIAL NUMBER 4017A58200
Washington, DC 20017
Danny  W.
Danny W. Checked in
FALL CHECK checked filter 16x25x1, checked indoor blower motor and wheel, cleaned and checked burners and heat exchanger, checked inducer draft motor and flue, cleaned and checked flame sensor, checked all safeties and limits, checked all water lines and tubes, checked condensate pump, checked aprilaire 700 humidifier found not working found humidifier fan motor stuck, checked temperature rise 40-70 return air temperature 74 , supply air temperature 117 CUSTOMER STATED THAT IT WAS REPLACED RECENTLY, NEED TO CHECK THE RECORDS PAYNE MODEL NUMBER PG92SC48100C SERIAL NUMBER 0215A52028
Bethesda, MD 20817
Danny V.
Danny V. Checked in
FALL MAINTENANCE ON TWO UNITS #1 Main unit 90% Gas furnace. This is a older unit. I checked and replaced filter with one Costumer provided. I checked indoor blower motor and 10mfd capacitor and found within specs. I checked the inducer draft motor and flue vent pipe found okay. I checked all wiring and connections and all limits and safetys found okay.i got a return air temperature of 70 and a supply air temperature of 135. I performed a combustion analyze test and got a reading of 50ppm. I checked flame sensor and ignitior found ok. I checked Condensate trap and condensate pump and flushed with a gallon of water and added Condensate tablets. I checked EVAP coil and found clogged with dirt and debris. Overall system is running and heating. In the near future I recommend clients start thinking about upgrading unit. Recommendations for unit #1: Clean coil $362.00 #1 Unit in the garage. Heat pump I checked the filter and replaced with one costumer provided. I checked electr
Sterling, VA 20164
Danny V.
Danny V. Checked in
FALL MAINTENANCE ON ONE UNIT 2016 CARRIER HEAT PUMP Client advised me that filters had been replaced upon today's arrival. I checked the indoor blower wheel motor housing compartment for any obstructions and noticed a fungle outbreak cultivating within the system near the blower , the wirings and the coil. I also noticed that the variable speed motor is exposed to any high voltage power surges due to it not containing a surge protector. I checked the electrical heater element and found okay. I checked Blower amps and found within specs. I checked all wiring and connections and all limits and safetys found working okay at this time. I got a return air temperature of 75 and a supply air temperature of 120. I checked the outdoor condenser coil and found okay. I checked the outdoor temperature, the discharge temperature and the liquid line/suction line temperature and found okay. I checked the double pole contactor amd found okay. I checked the 45/5 MFD Cap and found okay. i checked the f
Herndon, VA 20170
Brandon  B.
Brandon B. Checked in
I inspected 80 % gas furnace. I cleaned flame sensor. ignitor reading 56 ohms. I checked inducer amps and blower amps. return 74 supply 138. I tightened all wire connections and dampers in open positions. Co combustion reading 304 stack temp 9%oxygen and 49 ppm. System is heating properly at this time.
Washington, DC 20012
Brandon  B.
Brandon B. Checked in
I checked heat pump. filters clean at this time. heater kitt amps reading 20.13. blower motor pulling .98 amps. 70 supply 124. compressor pulling 4.19 fan .56. I checked capacitor and also tested defrost controls. indoor and outdoor coils are clean at this time. I do recommend 240v protector. I also service 80% gas furnace. I cleaned flame sensor and checked all safeties and switches. 16x25x1 filters need to be replaced. ignitor ohm is 53. I checked voltage at board and gas valve as well as tightened all 24 volt connections. return is 73 supply 133. Co combustion analysis test showed 328 stack temp, 11%oxygen and co 32 ppm. both systems are heating properly at this time. Thank you for choosing vito services.
Washington, DC 20016
Parris B.
Parris B. Checked in
Call to do maintenance on 2022 heat pump system. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower is clean along with evaporator coil. Checked air filter and water panel both are good. Checked condenser unit and found no issues as well. Final cycled system at this time system is operational.
Fairfax, VA 22033
Anthony V.
Anthony V. Checked in
Water Heater Making Sounds: was not able to get heater repeat sound. customer said she will record and get back with us
Germantown, MD 20874
Aaron W.
Aaron W. Checked in
arrive. Noone on site. rescedual. found that owner was home- turned back around. I stalled zone board zone operations normal boiler operating. owner refuse payment. Will pay when speak to office. old board only laster 2 years.
Lanham, MD 20706
Review
Great and fast
Jordan - Potomac, MD 20854
Review
Great service
Rita - Washington, DC 20011
Review
Excellent service from Vito
Ira - Washington, DC 20008
Review
Mr. Beam was exceptional. He recognized the problem and stayed with me until the issue was completely resolved. Excellent knowledge, professionalism, and super service!
Chris - Washington, DC 20005
Review
We used another company to install our system from Carrier and they were having issues. Aaron Wade with Vito came in and saved the day. He was not only knowledgeable but kind and made sure lol was fixed and working. Great work!!
Avi - Washington, DC 20007
Review
Danny's service is thorough and excellent. His friendliness earned his bonus points.
Hongda - Fairfax, VA 22033
Review
Aaron is the ultimate HVAC professional; he is knowledgeable, highly skilled, on time, and has a great personality. In a word, he is Outstanding!
Howard - Silver Spring, MD 20901
Review
Good work
Thomas - Washington, DC 20011
Review
Excellent Service
George - Washington, DC 20008
Review
Dennell was great, he worked quickly to solve a minor toilet rebuild.
Jordan - Potomac, MD 20854
Review
Prompt, Professional Service!
Interwork Office Solutions - Rockville, MD 20850
Review
Dennell was professional, thorough, and informative while conducting an annual plumbing inspection. He quickly assessed our plumbing needs, executed the necessary andjustments and provided amplifying information regarding our sump pump/water heater/faucets. This was our first VIP Club interaction with a VITO technician and Dennell was a great representative for the company.
Mike - Sterling, VA 20165
Review
Danny White came to our house for a regular boiler maintenance appointment. He performed the most complete service on our boiler that we have seen in 28 years. He found some things that needed attention and explained thoroughly why the work should be done.
Susan - Washington, DC 20007
Review
good service
Carla - McLean, VA 22101
Review
I received a friendly technician who completed the job promptly. He also explained the job to be done.
Paula - Haymarket, VA 20169
Review
Job well done
Daniel - Rockville, MD 20850
Review
Danny was efficient courteous and explained all to us.
Jay - Washington, DC 20024
Review
I needed my furnace and air conditioner replaced because they were both 22 years old and the furnace had stopped working this week. I requested a service call which was completed very promptly. I was given an explanation of the problem and the options for replacement. I did not shop around because I trusted Vito from previous experience. So, I anticipated that the cost would be significant. I was given a quote with a modest discount, which I accepted. The furnace and air conditioner were replaced 48 hours later and the work was done very efficiently, the technicians were extremely polite and they cleaned up after they were done. They showed me their work and asked me if I had any questions. I would say that the whole experience was positive and that it went very smoothly and to my satisfaction.
Nakissa - Bethesda, MD 20814
Review
Courteous, competent service
Bill - Haymarket, VA 20169
Review
Fabulous service: on time. Thorough. Thoughtful. Skillful. Articulate. Carful of my pets and the objects in my house. Kind. I am continuously pleased with Vito’s Services.
Linda - Silver Spring, MD 20906
Review
Mr. Beam helped me very much with my annual heating inspection. He was absolutely wonderful in taking care of everything involved with this appointment. He explained things thoroughly to me and was very patient in answering my questions about my heating system. And I really enjoyed talking with him about the various aspects of my HVAC system. I appreciate him very much. Sincerely, Mary Bizzigotti
Mary - Herndon, VA 20170
Review
Brandon is knowledgeable, thorough and professional,
Peggy - Bethesda, MD 20817
Response from Vito Services:

We count ourselves lucky for customers like you and look forward to working with you again in the future!

 

Trusted Quality & Service
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 301-315-6100 .

By pressing Submit I agree to receive phone, email, or text messages from Vito Services to the provided mobile number and also agree to the Vito Services terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next