Dependable HVAC & Plumbing Services In Sterling VA
At Vito Services in SterlingVA, we take pride in being the leading provider of heating, ventilation, air conditioning (HVAC), plumbing, and air quality management. Our comprehensive range of services includes everything from urgent repairs and precise installations to regular upkeep. Our team, driven by a commitment to excellence, focuses on enhancing the comfort and efficiency of your living spaces. We ensure your home remains warm in the winter, cool in the summer, and the air quality remains top-notch all year round. We also offer plumbing solutions that keep things flowing as they should so your family remains comfortable. Our expertise lies in catering to your specific needs with a dedication to superior service and customer contentment. Choose Vito Services to enjoy the assurance that comes with entrusting your home to Sterling’s most capable hands, and let us improve your living standards because you’re entitled to the best.
We are excited to welcome you to explore our wealth of positive feedback from our satisfied clients. Every 5-star review reflects the outstanding quality and commitment we invest in each task, regardless of its size. Through these personal experiences, you’ll get a glimpse into what sets Vito apart and the reason why the SterlingVA community relies on us for not only solutions but also for comfort and contentment. Experience firsthand the excellence and dedication that distinguish us by reviewing these testimonials. Become a part of the Vito family today and discover the remarkable service we pride ourselves on!
Recent Jobs and Reviews in Sterling, VA
Our Local Reviews by City
- Adelphi, MD (3)
- Aldie, VA (1)
- Alexandria, VA (6)
- Arlington, VA (2)
- Ashburn, VA (5)
- Aspen Hill, MD (2)
- Berwyn Heights, MD (1)
- Bethesda, MD (34)
- Bowie, MD (3)
- Boyds, MD (1)
- Brambleton, VA (1)
- Brookeville, MD (1)
- Burke, VA (1)
- Cabin John, MD (1)
- Centreville, VA (3)
- Chantilly, VA (4)
- Chevy Chase, MD (10)
- Clarksburg, MD (1)
- College Park, MD (1)
- Damascus, MD (1)
- Derwood, MD (1)
- Fairfax, VA (14)
- Fairfax Station, VA (3)
- Fort Washington, MD (3)
- Frederick, MD (2)
- Gaithersburg, MD (13)
- Germantown, MD (6)
- Great Falls, VA (2)
- Haymarket, VA (11)
- Herndon, VA (9)
- Hyattsville, MD (3)
- Kensington, MD (3)
- Laytonsville, MD (1)
- McLean, VA (4)
- Montgomery Village, MD (1)
- North Bethesda, MD (4)
- North Potomac, MD (1)
- Oakton, VA (3)
- Olney, MD (7)
- Poolesville, MD (1)
- Potomac, MD (17)
- Potomac Falls, VA (1)
- Reston, VA (3)
- Rockville, MD (23)
- Silver Spring, MD (37)
- Springfield, VA (1)
- Sterling, VA (1)
- Takoma Park, MD (1)
- Upper Marlboro, MD (1)
- Vienna, VA (4)
- Washington, DC (86)
Job Locations and Reviews
HEAT ONLY WORKING ON EMERGENCY HEAT checked thermostat set to regular heat, checked air handler to see if contactor was sticking, checked heat pump operation found working heating fine, outdoor air temperature 49, , discharge air temperature 42 , return air temperature 66 , supply air temperature 93 , checked filter 20x20x1, didn't find anything wrong with the system working heating fine, checked emergency heat found working fine GOODMAN MODEL AIR HANDLER NUMBER AVPTC48C14AB SERIAL NUMBER 1511125458 GOODMAN HEAT PUMP MODEL NUMBER D8ZC160481AE SERIAL NUMBER 1408179123
Fix Toilet In Ladie's Room: arrived at location for a replacement of fill vale, noticed the flapper was not holding either so replace flapper and fill vale and supply tube as well, this world was. done on the second floor women restroom. no leaks occured.
FAN HUMIDIFIER NOT WORKING. Upon arrival the client advised me that they heard a loud noise coming from humidifier and noticed water just dripping down pipe. I checked humidifier copper feed tube and valve. The valve was kinda stuck. But there was water. I checked the first end of the solenoid valve and there was water and also the other end of the solenoid valve there was water so water was not the problem. I checked the humidifier connections at the 24v and found okay and in tact. The 120V for the fan is going into a junction box at the furnace. There was 120v present but the fan never kicked on. The issue is the fan motor form the humidifier. I did advise the client and he is now aware of the source. I spoke to him about the part and the cost without any warranty. But I also spoke to the client about upgrading the humidifier to an April air700 humidifier that includes 12 months warranty. The price for just fan motor for humidifier is $958.00 The price for a new humidifier includ
Heat Inspection: System is a 2022 80% Furnace/AC. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower in clean along with evaporator coil. System does not have a Air Scrubber or Humidifier. Filter needs to be changed. Final cycled system at the time system is operational. Customer asked about duct cleaning and I suggested adding an air scrubber afterwards. Duct Cleaning $897 Air Scrubber $1,300
Commercial HVAC Call, No Heat, Thermostat Not Connected: Arrived. checked reznor ceiling hung heater found no 120 voltage going to it seems the BX cable was cut, will a electrician to locate all the cut wires in this warehouse, she asked about the AC , don't see a air handler but do see flex duct supply and return, and thermostat wires going to the roof
FALL MAINTENANCE ON ONE 80% CARRIER GAS FURNACE 2017. I checked the filter and found okay as of now, the client has replaced it upon today's arrival. I checked the indoor blower wheel motor and wheel housing for any debris and found none. I checked the 10mfd capacitor and found okay. I checked blower amps and found within specs. I checked the Inducer draft motor and flue vent pipe and found okay. I checked Inducer amps also within specs. I cleaned and checked the burners and heat exchanger. I checked the flame sensor found ok, does have some wear on it, but I did clean it off today. I checked the Ignitor reading 55ohms and found okay. I checked all limits and safety and all wiring and connections found okay. I got a return air temperature of 80 and a supply air temperature of 118. I recommend checking the 1inch filter every 30 days and change accordingly. Also , moving forward we will keep an eye on the flame sensor due to its wear and tear. Over all the system is running and heating
System is a 2015 80% Furnace/AC. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower in good condition along with evaporator coil. System does have a UV light. Changed air filter. Checked UV light and found it still lit. Final cycled system at this time system is operational.
arrived onsite, flushed water heater for approximately 30 minutes. noticed unit is 21 years old and brought it to customer's attention. customer wants to hold off on replacing it for now. duct taped water heater insulation jacket back together before leaving.
FALL MAINTENANCE ON TWO UNITS. #1 Carrier 80% Gas furnace. I checked the 16251 filter, the client advised me he changes it every 90 days. I checked the indoor blower wheel motor housing compartment for any obstructions and found none. Blades on blower housing are clean. I checked the 7.5mfd capacitor and found it okay reading within specs. I checked the blower amps and found okay. I checked the Inducer draft motor and flue vent pipe and found functioning properly. I checked inducer amps. I checked the Ignitor reading 52ohms. I checked the flame sensor and found it had wear on it. I cleaned it off for today but the micro amps are low at .3 micro amps. I checked all limits and safetys and all wiring and connections found okay. I checked the humidifier and water panal but the client doesn't use it at all. I got a return air temperature of 65 and a supply air temperature of 105. I checked the gas valve 24v working properly. This unit in running and heating as of now with good temperatur
AIR FLOW ISSUES Client advised me that the air flow was wrong. When he switched the dampers the main floor will be hot but the upstairs will be freezing. Or vise versa. Dampers are loose but I adjusted it so they the equal amount of heat will be released through the supply on the main floor and on the top floor for all three rooms. After adjusting dampers. I took temperature on all vents and got a supply air temperature of 120 on all vents on main floor and top floor. Also walked through it with client so he could see for himself. Checked operation found ok for now. We will keep an eye on this unit moving forward due to last tech that was here was getting a high reading of CO. If there is any issues , question or concerns please give us a call. Thank you for choosing VITO SERVICES. Dispatch fee $120.00 Minor repair $100.00
System is a 2018 Heat pump . Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found blower clean along with evaporator coil. System does not have a UV light but does have a humidifier. Humidifier needs new pad ($206). Air filter is good. Checked condenser unit and found system is amping within specs. Tested starting components (contactor & capacitor) and checked for any loose connections. Cycled defrost successfully. Final cycled system at this time system is operational. Recommended adding ECM Surge Protector to blower ($160).
REPLACE HVAC PART replaced roof top package unit gas valve, checked operation unit is working heating fine.
Unit Not Running, Outside Unit is Not Coming On: explain functions of duel fuel. I set to gas furnace only
NO HEAT checked rooftop package unit found bad gas valve, need to order part DEPOSIT FOR PART 250.00 CARRIER MODEL NUMBER 48TCED08A2A5AOAO SERIAL NUMBER 3615P73610
FALL MAINTENANCE ON TWO UNITS #1 Main unit 90% Gas furnace. This is a older unit. I checked and replaced filter with one Costumer provided. I checked indoor blower motor and 10mfd capacitor and found within specs. I checked the inducer draft motor and flue vent pipe found okay. I checked all wiring and connections and all limits and safetys found okay.i got a return air temperature of 70 and a supply air temperature of 135. I performed a combustion analyze test and got a reading of 50ppm. I checked flame sensor and ignitior found ok. I checked Condensate trap and condensate pump and flushed with a gallon of water and added Condensate tablets. I checked EVAP coil and found clogged with dirt and debris. Overall system is running and heating. In the near future I recommend clients start thinking about upgrading unit. Recommendations for unit #1: Clean coil $362.00 #1 Unit in the garage. Heat pump I checked the filter and replaced with one costumer provided. I checked electr
FALL MAINTENANCE ON ONE UNIT. 2010 Carrier 80% GAS FURNACE. i checked the filter and found it had been replaced upon today's arrival. I went to home Depot to buy a #35 humidifier water panal per nolan. I replaced water panel. I checked the indoor blower wheel motor housing compartment for any obstructions and found none. i checked motor amps and found okay. I checked the inducer draft motor and flue vent pipe and found ok. I checked inducer amps and found within specs. I checked and cleaned burners and heat exchanger. I checked flame sensor and ignitior and found both none reliabile anymore. I checked all wiring and connections and all limits and safetys found okay. I got a return air temperature of 70 and a supply air temperature of 130. Over all unit is running and heating as of now. Recommendations after today's visit: Replace flame sensor $300.00 Replace Ignitor $400.00 The client has agreed to do additional work. I replaced flame sensor and ignitior today and will c
FALL MAINTENANCE ON ONE UNIT 2017 CARRIER 80% GAS FURNACE I checked the filter and replaced with one costumer provided. I checked the indoor blower wheel motor housing compartment for any obstructions and found none. I noticed that the variable speed motor is exposed to any high voltage power surges due to not containing a surge protector. I checked motor amps and found within specs. I checked the inducer draft motor and flue vent pipe and found okay. Inducer amps are within specs. I checked and cleaned burners and heat exchanger. I checked the Ignitor and appears to have been replaced about a year or two ago and in great condition. I checked the flame sensor and found wear and tear on it making it no longer reliable. I checked all limits and safetys. All wiring and connections found okay. I checked humidifier and found working as of now. I replaced #35 hum pad with one Costumer provided. I got a return air temperature of 70 and a supply air temperature of 130. I looked around the ex
Hi Mike - Welcome to the Vito Family! We are so glad to hear that you were pleased with plumbing technician on your first Vito VIP Club. Thank you for taking the time to let us know about your experience and for the 5-Star Review!
upon arrival of home I performed a plumbing inspection found a bad sump pump. price to replace is $1072 customer will call if he wants to replace
FALL MAINTENANCE ON TWO UNITS I checked filters for both units and replaced with one costumer provided. I checked full operation of unit. On low heat and high heat. Temperatures are great. Parts are reliable. All wiring and connections ok all limits and safetys ok. Amps are within specs. Both units have a ECM motor with no surge protection. As of right now the motors are exposed to any high voltage power surges. Overall units are running okay for now. Recommendations: Add Ecm surge protector $309.00x2
Fall Maintenance: i inspected 2016 carrier 80 gas furnace. I cleaned flame sensor. homeowner will purchase and replace 20x25x1 as well as 35 humidifier pad. I checked ignitor 46. inducer amps 1.2 blower amps 2.7. return 71 supply 133. I also completed combustion analysis stack temp is 348,oxygen 7.3, 66 ppm. system is heating properly at this time thank you for choosing vito services.
Performed maintenance on 2010 80% furnace/AC. Checked all components for proper operation found no issues with components. Secured any loose wires and checked for dirt and debris. Found fan is slightly dirty. Water panel in humidifier needs to be changed. Filter is clean. Performed combustion analyzer test and found system has high readings for C02 at 80-84 ppm. The system is starting to be unsafe. Recommended replacing system because of age and condition of system. Full Furnace and AC is $13,000+ depending on the system
Call to do maintenance on 2023 heat pump. During maintenance checked all components for proper operation found no issues with components. Checked for loose wires and any dirt. Filter does need to be changed. System is clean and all wires are connected properly. Recommended customer add humidifier to help with make home more comfortable. $1300
Call to do maintenance on 2024 Heat pump/ Furnace. During inspection found system is in great condition and still new. Cycled system completely at this time systems components are all working properly and are clean. At this time system is fully operational.
change furnace AC and coil. run new vinyl tube for new condensate pump
HVAC Error Code: Upon arrival customer concerns system is giving low pressure code. Checked system found 2017 90% furnace inducer motor is have a hard time because of water back up. Drained port and cycled system at this time system is full operational. Thank you for choosing vito